Samsung AC HCADKH Series Installation Manual page 13

Table of Contents

Advertisement

Connecting the cable
Power Cable Specifications
f The power cable is not supplied with air conditioner .
X
- Select the power supply cable in accordance with relevant local and national regulations .
- Wire size must comply with the applicable local and national code .
- Specifications for local wiring power cord and branch wiring are in compliance with local cord .
Single Phase
Model
Type of
outdoor
Outdoor Unit
unit
AC030HCADKH
A
AC036HCADKH
AC042HCADKH
B
AC048HCADKH
3 Phase
Model
Type of
outdoor
Outdoor Unit
unit
AC036HCADNH AC036HBMDKH
A
AC042HCADNH AC042HBMDKH
B
AC048HCADNH AC048HBMDKH
1 . Voltage range
- Units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above
NOTE
listed range limits
2 . Maximum allowable voltage variation between phases is 2 % .
3 . Wire size & type must comply with the applicable local and national code .
- Wire size : Based on the value of MCA .
- Wire type : 60245 IEC57(IEC) or H05RN-F(CENELEC) grade or more .
4 . MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker) .
5 . MCA represents maximum input current .
MFA represents capacity which may accept MCA
❋ ❋ Abbreviations
- MCA : Min . Circuit Amps . (A)
- MFA : Max . Fuse Amps . (A)
CAC_Global Duct Latin America_IM_EN_04680A-02.indd 12
Outdoor Units
Rated
Voltage Range Outdoor (Down_Amp)
Indoor Unit
Hz
Volts
Min.
AC030HBMDKH
60
220-240
AC036HBMDKH
60
220-240
AC042HBMDKH
60
220-240
AC048HBMDKH
60
220-240
Outdoor Units
Rated
Voltage Range Outdoor (Down_Amp)
Indoor Unit
Hz
Volts
Min.
60
380-415
342
60
380-415
342
60
380-415
342
ENGLISH-12
Input Current [A]
Max.
Cooling
Heating
198
264
24
24
198
264
24
24
198
264
24
24
198
264
24
24
Input Current [A]
Max.
Cooling
Heating
418
12
12
418
12
12
418
12
12
Power Supply
Indoor
Total
MCA
MFA
2 . 7
26 . 7
26 . 7
30
2 . 7
26 . 7
26 . 7
30
2 . 7
26 . 7
26 . 7
30
2 . 7
26 . 7
26 . 7
30
Power Supply
Indoor
Total
MCA
MFA
2 . 7
14 . 7
14 . 7
16 . 2
2 . 7
14 . 7
14 . 7
16 . 2
2 . 7
14 . 7
14 . 7
16 . 2
2014-09-04 오전 9:17:10