Set-Up and Operation

Ground Fault Circuit Interrupter (GFCI)

The machine MUST be connected to a properly earthed 240VAC mains electrical socket. Do
NOT use the machine with a non-earthed electrical supply. Do NOT use the machine with an
extension cord that is not properly earthed. If there is any doubt regards proper earthing of the electrical
supply, have a qualified electrician inspect and verify it. • If the GFCI green indicator light does not switch off
when TEST is pushed, do not use the machine until it is properly tested and repaired. • If the appliance does
not start, or stops while running, or if you experience an electric shock, switch the machine OFF and
disconnect it from the electrical supply immediately. Do NOT use the machine until it is properly tested and
repaired. • The electrical cable is not protected by the GFCI device from the GFCI device to the electrical
cable plug.
The tool is equipped with a ground fault circuit interrupter (GFCI), which reduces
the risk of electric shock. Check that the electrical mains socket that the machine
is connected to is properly grounded and test the GFCI before each use. To test:
Connect the machine into a grounded 240VAC electrical outlet and switch
the power ON.
Press the TEST button on the GFCI – the green indicator light should switch
off and power to the appliance should cut off.
To restore power after testing, push the RESET button.
If the GFCI is tripped due to an earth leakage situation, the power is cut to the
machine, the green indicator lamp switches off and the red warning lamp
illuminates. Switch the machine OFF and disconnect it from the electrical supply immediately. Do NOT use
the machine until it is properly tested and repaired.

Extension Leads

When using an extension lead, ensure it is a 3-wire (grounded) type with wiring of sufficient gauge. The
usage of a smaller gauge wire could lead to excessive overheating of the motor and the cable.
10
AWG 14

Tool Set-Up

Place the motor switch in the "OFF" position and disconnect the machine from the electrical
supply before assembling or making any adjustments to the tool. • Do NOT operate the
equipment with any safety device removed. • Use appropriate personal protective equipment while handling
and using the equipment. • Before use, check for broken, worn, missing, misaligned or binding parts, cable
wear or damage, or any other condition which may prevent safe and normal operation and remedy them
before operating the machine.
The tool is designed for wet drilling into concrete and stone using diamond core bits.
1. Check the appliance and cutting tools for wear or damage. If necessary, replace worn or damaged parts
before using the machine. Dull or damaged cutting tools can lead to binding, breakage, slower cutting
and increased wear and stresses to the tool.
2. Test the GFCI.
E&OE
Extension Cord Length (Metres)
20
AWG 12
©2017 Bäumr-AG
>30
Not recommended
5