Table A-1. Customer Commands - Comtech EF Data LBC-4000 Installation And Operation Manual

L-band up/down converter system
Table of Contents

Advertisement

LBC-4000 L-Band Up/Down Converter System
Remote Control
Command
Parameter
(Instruction
Type
Code and
qualifier)
Operating
FRE_
Frequency
Attenuation
ATT_

Table A-1. Customer Commands

Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric
Response to
codes, that is, ASCII codes between 48 and 57)
Query
11 bytes,
Command or Query.
alphanumeric
FRE_x_yyyyy.yyy
Where: x = 'A' (converter A) or 'B' (converter B)
yyyyy.yyy =Valid Operating frequency, in MHz and
1-kHz step.
Example: FRE_A_00951.000
It means converter A is set to 951 MHz. The user
has the option to set it at Ku-Band frequency for
example, 14500.000 MHz, if the 'frequency display
select' option is turned ON.
7 bytes,
Command or Query.
alphanumeric
ATT_x_yy.yy
Where: x = 'A' (converter A) or 'B' (converter B)
yy.yy = Valid attenuation level, in dB, at 0.1-dB
step size as factory default.
Example: ATT_A_12.20
Converter A is set to 12.20 dB.
MN/LBC4000.IOM
Revision 2
Response to
Command
(target to
controller)
Same as command
Same as command
A-7
Query
Response to
(Instruction
Query
Code and
(target to
qualifier)
controller)
FRE_x_
FRE_x_yyyyy.yyy
(see description of
arguments)
ATT_x_
ATT_x_yy.yy
(see description of
arguments)

Advertisement

Table of Contents
loading

Table of Contents