ATM/POS bridge | Installation Manual
5. If the bridge is switched on, a welcome message is shown on the screen. This
message prompts you to press the F1 key (a function key on your keyboard).
6. Press the F1 key; the screen displays the System Options Menu.
7. To configure the bridge, navigate through the menus using the numeric keys on your
keyboard to select menu items.

2.2 Configuration menus

2.2. 1 System options menu
The system options menu has 6 items:
1. Network Setup
2. Communication Channels
3. Terminal Setup
4. Simulation mode
5. Recording Language
6. Service Menu
Network Setup
The Network Setup submenu enables you to configure network settings and enter a
bridge name:
1
Bridge Name
2
IP-Address
3
Subnet Mask
4
Default Gateway
5
Recorder TCP Port
6
Service TCP Port
The MAC Address of the bridge is shown but cannot be changed.
Bosch Security Systems
BRIDGE-01
192. 1 68. 1 0.2
255.255.255.0
0.0.0.0
4200 (default)
4201 (default)