SAFETY MESSAGE TO INSTALLERS
People's lives depend on your safe installation of our products.
It is important to read, understand and follow all instructions
shipped with the products. In addition, listed below are some other
important safety instructions and precautions you should follow:
To properly install this light: you must have a good
understanding of automotive electrical procedures
and systems, along with proficiency in the installa-
tion and use of safety warning equipment.
DO NOT install equipment or route wiring in the
deployment path of an air bag.
When drilling into a vehicle structure, be sure that
both sides of the surface are clear of anything that
could be damaged.
In order for the light to function properly, a good
ground connection must be made. At a minimum, it
must be attached to a solid metal body or chassis
part that will provide an effective ground path as
long as the light system is to be used.
Locate light control so the VEHICLE and CON-
TROL can be operated safely under all driving
conditions.
Do not attempt to activate or deactivate light control
while driving in a hazardous situation.
This product controls high intensity LED devices. To
prevent eye damage, DO NOT stare into the light
beam at close range.
You should frequently inspect the light to ensure
that it is operating properly and that it is securely
attached to the vehicle.
File these instructions in a safe place and refer to
them when maintaining and/or reinstalling the
product.
Failure to follow all safety precautions and instructions may
result in property damage, serious injury, or death to you or
others.
I.
GENERAL.
The Federal Signal SignalMaster Model 330103 is an
economical, low profile, solid state, directional light control that is
designed to operate with any of Federal Signal's SignalMaster
series eight-lamp directional lights. This control will also operate
two sets of external lamps (Federal Signal Models 320102,
SMLED1, 320112, and 320721, or other 50 watt lamps). The unit
is reversed polarity protected to avoid damage if the positive and
negative power connections are connected incorrectly.
This model provides three distinctive directional signals, left
arrow, right arrow, and center out. An alternating flash pattern
produces a warning signal for use when a directional signal may
not be appropriate. In addition, an auxiliary flash pattern
alternately flashes the external lamps. When a directional signal
is selected, the lamps individually activate sequentially in a
sweeping motion until all eight are illuminated. The slide switch
overrides the WARN and AUX functions
INSTRUCTION SHEET
FOR
SIGNALMASTER™ MODEL 330103
external controls and lights into the SignalMaster system. When
properly connected, a positive (+)12 volts applied to the AUX IN
terminal will activate the alternating flash pattern. The AUX OUT
terminal can activate a ground-activated relay ( user-supplied)
when the AUX switch is operated.
II.
Input Voltage
Polarity
Operating Temperature
Range
Standby Current
+BAT Fuse
+IGN/BAT Fuse
AUX OUT Fuse
Output Drive
Capability (Total)
Flash Rate:
Dimensions:
III.
tions packed with the 320340 universal mounting kit. Route the
cable near the eventual location of the control unit.
control unit to be mounted in a variety of positions. To install the
control unit, proceed as follows:
An auxiliary input and output are provided for integrating
WARNING
These lights are intended for secondary warning only.
They are not intended for use as a primary warning
system.
SPECIFICATIONS.
11VDC to 16VDC.
Negative ground only.
-30° C to +65° C.
Zero amperes.
25 amperes.
1 ampere.
1 ampere.
Directional
8, 27 watt lamps.
Auxiliary
4, 27 watt lamps (2 per output) or
Directional
35 patterns/min.
Warn
60 patterns/min.
Height
1-1/2"
Width
6-1/8"
Depth
5"
Shipping Weight
2.0 lbs.
INSTALLATION.
WARNING
When installing equipment inside air bag equipped ve-
hicles, the installer MUST ensure that the equipment is
installed ONLY in areas recommended by the vehicle
manufacturer.
Failure to observe this warning will reduce the effective-
ness of the air bag, damage the air bag, or potentially
damage or dislodge the equipment, causing serious injury
or death to you or others.
A.
SignalMaster Light Assembly.
Install the light assembly as described in the instruc-
B.
Control Unit.
See figure 1. The supplied mounting bracket allows the
2, 50 watt lamps (1 per output).

Advertisement

loading
Need help?

Need help?

Do you have a question about the Signalmaster 330103 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Federal Signal Corporation Signalmaster 330103

  • Page 1 2561006D REV. D 502 Printed in U.S.A INSTRUCTION SHEET SIGNALMASTER™ MODEL 330103 An auxiliary input and output are provided for integrating SAFETY MESSAGE TO INSTALLERS external controls and lights into the SignalMaster system. When People’s lives depend on your safe installation of our products. properly connected, a positive (+)12 volts applied to the AUX IN It is important to read, understand and follow all instructions terminal will activate the alternating flash pattern.
  • Page 2 The control unit is supplied with a six-position connector SCREWS,THREAD FORM., and a eleven-position connector to perform the electrical installa- USER SUPPLIED tion. User-supplied, 14-gauge red and black wires are required for the (+) BAT and (-) GND connections on the six-position connector. User-supplied, 18-gauge red and green wires are required for the (+) BAT/IGN and CASE GROUND connections on the six-position 1/4-20 x 3/8"...
  • Page 3 Ensure that there are no loose wire strands or other bare wires which may cause a short circuit. Also, all wires must be SignalMaster FEDERAL SIGNAL CORPORATION protected from any sharp edges which could eventually cut through the insulation. 330103 290A2542-39B Figure 4.
  • Page 4 Communication and shipments should be addressed to: flashing pattern, instructing traffic to move right. Service Department WARN switch. Federal Signal Corporation 2645 Federal Signal Drive When this switch is pressed, an alternating pattern is University Park, IL 60466 produced. The four middle lights activate alternately with the two outside lights on each side.