HELP MODE SYMBOLS AND ELEMENTS

Along with the steps of the help mode, symbols and elements are mapped, at all times, to reflect the state of various inputs and outputs.
Dryer (Upper)
Display Symbol
°
OR
&
*
Help Mode Button Function Table
Button Name
on Interface
LOWER LEFT
(HOT) BUTTON
LOWER RIGHT
(COLD) BUTTON
LOWER MIDDLE
(WARM) BUTTON
Dryer Drive Motor Resistance
Resistance
Winding
MAIN
2.4–3.6 Ω
START
2.4–3.8 Ω
Dryer Exhaust Temperatures
Fabric Setting
Heat Turns Off*
Cotton/
Whites
Perm
Press
Colors/
Delicates
*The measured overshoot using the glass bulb thermometer in the exhaust outlet
can be 30°F (17°C) higher.
Dryer Gas Valve Resistance
Terminals
1 to 2
1 to 3
4 to 5
IMPORTANT: Make sure all harness wires are looped back
through the strain relief after checking or replacing coils.
Description
Dryer motor sensed on
Dryer door sensed closed
Dryer heater relay on
Dryer motor relay on
Low voltage sensed
Generic
Button Function
Slew
Exits help mode and returns to set-up mode –
either dAS display or Manual Set-up Mode (2.)
Mode Select
Inactive – no result
Mode Advance
Advances to next help mode screen
Contact Points
(Ω)
of Measurement
Lt. blue wire in back at pin 4
and bare copper wire on pin 5
of black drive motor switch.
Lt. blue wire in back at pin 4
and bare copper wire on pin 3
of black drive motor switch.
Heat Turns On
155° ± 5°F
10–15°F
(68° ± 3°C)
(6–8°C)
155° ± 5°F
Below the
(68° ± 3°C)
heat turn off
temperature
140° ± 5°F
(60° ± 3°C)
Resistance
1365 Ω ± 25
1560 Ω ± 25
1220 Ω ± 50
Washer (Lower)
Display Symbol
WASH
RE
°
DOOR LOCKED
COLD
HOT
OR
AVAILABLE
Result While
Help Code Not Displayed
Dryer Temperature and Thermistor Values
Fabric
Setting
Cotton/
Whites
Perm
Press
Colors/
Delicates
Dryer Thermistor Resistance
Temp.
°F (°C)
50°F (10°C)
60°F (16°C)
70°F (21°C)
PAGE 14
Description
Water sensed above wash level
Washer redistributing due
to out-of-balance condition
Washer door sensed closed
Washer door sensed locked
Cold water output on
Hot water output on
Door unlock output on
Washer drain pump output on
Result While
Help Code Displayed
Exits help mode and returns to set-up mode –
either dAS display or Manual Set-up Mode (2.)
Clears all three help codes
Advances through each help code or from last
to the extended fill option
resistance value
at heater shutoff
(digital or analog
Temperature
155° ± 5°F
2.1
(68° ± 3°C)
155° ± 5°F
2.1
(68° ± 3°C)
140° ± 5°F
2.8
(60° ± 3°C)
Thermistor Resistance
Res.
Temp.
°F (°C)
19.9
80°F (27°C)
15.3
90°F (32°C)
11.9
100°F (38°C)
Thermistor
meter) kΩ
1.7
1.7
2.3
Res.
9.2
7.4
5.7