Chapter 4
Installation & Setting-up Operation
Installation of Optional Wing Assemblies
Wing assemblies are attached to either side of an Apex applicator in order to give
additional stability to a moving substrate. Two wing assemblies are required per
application, either a right and left pair, or two universal wing assemblies.
1. Assemble each of the two wing assemblies for the applicator.
2. Align the wing assemblies with the die lips of the Apex slot die.
3. Attach wing assemblies by tightening the M6 bolts. Use a 0.010 feeler gauge to set
clearance between the die lips and the end of the wing. The feeler gauge should slip
between the two assemblies after tightening all bolts.
4. Tighten the M4 bolts.
Left Wing
APEX Slot Die Applicator
Apex Slot Die Applicator, Manual #40-47, Rev. 10.16
Right Wing