Adhesive Application Solutions | ISO 9001 certified APEX SLOT DIE APPLICATOR Technical Documentation, No.40-47, Rev.10.16 ITW Dynatec An Illinois Tool Works Company www.itwdynatec.com...
ITW Dynatec Information about this manual Information about this manual Read all instructions before operating this equipment! It is the customer’s responsibility to have all operators and service personnel read and understand this information. Contact your ITW Dynatec customer service representative for additional copies. NOTICE: Please be sure to include the serial number of your application system each time you order replacement parts and/or supplies.
Index ITW Dynatec Index Information about this manual ..........2 Index ..................3 Chapter 1 Declaration of Incorporation / Conformity ... 7 Chapter 2 Safety Instructions ..........9 General Considerations ......................9 Warning Labels ......................... 9 Safety Symbols in this Manual ....................10 Safe Installation and Operation ....................
Page 4
ITW Dynatec Index Installation of Optional Wing Assemblies ................35 4.3 Quality of compressed Air ................36 4.4 Advices for the setting-up operation ............. 37 4.5 Setting-up operation, in general ..............38 4.5 Shut Down Procedure ................... 40 Chapter 5 Maintenance and Repair Notes ......41 5.1 Security advices for maintenance and repair ..........
Page 5
Index ITW Dynatec APEX Slot Die Module, with MAC solenoid valve ..............82 APEX Slot Die Module, with MAC solenoid valve and air tubes ..........83 APEX Slot Die Module, (rectangle stand-off), with Festo solenoid valve ....... 84 APEX Slot Die Module, (square stand-off), with Festo solenoid valve ........84 Block-Off Module, square stand-off, PN 809956 ..............
Page 6
ITW Dynatec Index This page intentionally left blank. Page 6 Apex Slot Die Applicator, Manual #40-47, Rev. 10.16...
Chapter 2 ITW Dynatec Safety Instructions Chapter 2 Safety Instructions General Considerations All operators and service personnel must read and understand this manual before operating or servicing equipment. All maintenance and service on this equipment must be performed by trained technicians.
ITW Dynatec Chapter 2 Safety Instructions Safety Symbols in this Manual 1. WARNINGS and CAUTIONS are found throughout this manual. WARNINGS mean that failure to observe the specific instructions may cause injury to personnel. 2. CAUTIONS mean that failure to observe the specific instructions may damage the equipment.
Chapter 2 ITW Dynatec Safety Instructions Explosion/ Fire Hazard 1. Never operate this unit in an explosive environment. 2. Use cleaning compounds recommended by ITW Dynatec or your adhesive supplier only. 3. Flash points of cleaning compounds vary according to their composition, so consult with your supplier to determine the maximum heating temperatures and safety precautions.
ITW Dynatec Chapter 2 Safety Instructions Electrical DANGER HIGH VOLTAGE 1. Dangerous voltages exist at several points in this equipment. To avoid personal injury, do not touch exposed connections and components while input power is on. 2. Disconnect, lockout and tag external electrical power before removing protective panels.
Chapter 2 ITW Dynatec Safety Instructions High Pressure WARNING HIGH PRESSURE PRESENT 1. To avoid personal injury, do not operate the equipment without all covers, panels and safety guards properly installed. 2. To prevent serious injury from molten adhesive under pressure when servicing the equipment, disengage the pumps and relieve the adhesive system's hydraulic pressure (i.e.
ITW Dynatec Chapter 2 Safety Instructions Servicing, maintenance 1. Only trained and qualified personnel are to operate and service this equipment. 2. Before any service work disconnect the external power supply and the pressure air supply! 3. Never service or clean equipment while it is in motion. Shut off the equipment and lock out all input power at the source before attempting any maintenance.
Chapter 2 ITW Dynatec Safety Instructions Treatment for Burns from Hot Melt Adhesives Measures after being burned: 1. Burns caused by hot melt adhesive must be treated at a burn center. Provide the burn center's staff a copy of the adhesive's M.S.D.S. to expedite treatment. 2.
ITW Dynatec Chapter 2 Safety Instructions Keep attention to environmental protection standards 1. When working on or with the unit, the legal obligations for waste avoidance and the duly recycling / disposals have to be fulfilled. 2. Keep attention, that during installations, repairs or maintenance matters hazardous to water, like adhesive / adhesive scrap, lubricating grease or oil, hydraulic oil, coolant and cleaner containing solvent not pollute the ground or get into the canalization! 3.
Chapter 3 ITW Dynatec Description and Technical Specs Chapter 3 Description and Technical Specs 3.1 Applicable Safety Regulations Intended Use The APEX High-Speed Intermittent Slot Die Applicator may be used only to apply suitable materials, e.g. adhesives. When in doubt, seek permission from ITW Dynatec. If the Applicator is not used in accordance with this regulation, a safe operation cannot be guaranteed.
ITW Dynatec Chapter 3 Description and Technical Specs Technical changes Any kind of technical changes having impact to the security or the operational liability of the system should only be done by written agreement of ITW Dynatec. Suchlike changes made without given a corresponding written agreement will lead to immediate exclusion of liability granted by ITW Dynatec for all direct and indirect subsequent damages.
Chapter 3 ITW Dynatec Description and Technical Specs 3.2 Description APEX Slot Die Applicator Description ITW Dynatec’s APEX High Speed Intermittent Slot Die Applicator is an air-operated hot melt adhesive applicator assembly with an optional filter manifold. The applicator is used with intermittent pressure and constant pressure hot melt adhesive supply units (ASUs).
Chapter 3 ITW Dynatec Description and Technical Specs Dimensions: APEX 50 mm with MAC Valve Applicator shown is a 50 mm slot die with Mac valve, 40 mm pattern and optional filter manifold. Dimensions are expressed as “mm [inch]”. Apex Slot Die Applicator, Manual #40-47, Rev. 10.16 Page 21...
ITW Dynatec Chapter 3 Description and Technical Specs Dimensions: APEX 50 mm with Festo Valve Applicator shown is a 50 mm slot die with Festo valve, 40 mm pattern and optional filter manifold. Dimensions are expressed as “mm [inch]”. Page 22 Apex Slot Die Applicator, Manual #40-47, Rev.
Chapter 3 ITW Dynatec Description and Technical Specs Dimensions: APEX 50 mm with MAC Valve, tube-mount Applicator shown is a 50 mm slot die with MAC valve, tube-mount, 40 mm pattern and optional filter manifold. Dimensions are expressed as “mm [inch]”. Apex Slot Die Applicator, Manual #40-47, Rev.
ITW Dynatec Chapter 3 Description and Technical Specs Dimensions: APEX 76.2 mm with MAC Valve Applicator shown is a 76.2 mm slot die with Mac valve, 50 mm pattern and optional filter manifold. Dimensions are expressed as “mm [inch]”. Page 24 Apex Slot Die Applicator, Manual #40-47, Rev.
Chapter 3 ITW Dynatec Description and Technical Specs Dimensions: APEX 110 mm with MAC Valve Applicator shown is a 110 mm slot die with Mac valve, 40 mm pattern and optional filter manifold. Dimensions are expressed as “mm [inch]”. Apex Slot Die Applicator, Manual #40-47, Rev. 10.16 Page 25...
ITW Dynatec Chapter 3 Description and Technical Specs Dimensions: APEX 150 mm with MAC Valves Applicator shown is a 150 mm slot die with Mac valves, 80 mm pattern and optional filter manifold. Dimensions are expressed as “mm [inch]”. Page 26 Apex Slot Die Applicator, Manual #40-47, Rev.
Chapter 3 ITW Dynatec Description and Technical Specs Dimensions: APEX 190 mm with MAC Valves Applicator shown is a 190 mm slot die with Mac valves, 120 mm pattern and optional filter manifold. Dimensions are expressed as “mm [inch]”. Apex Slot Die Applicator, Manual #40-47, Rev. 10.16 Page 27...
ITW Dynatec Chapter 3 Description and Technical Specs Dimensions: APEX 270 mm with MAC Valves Applicator shown is a 270 mm slot die with Mac valves, 200 mm pattern and optional filter manifold. Dimensions are expressed as “mm [inch]”. Page 28 Apex Slot Die Applicator, Manual #40-47, Rev.
Chapter 3 ITW Dynatec Description and Technical Specs Dimensions: APEX 390 mm with MAC Valves Applicator shown is a 390 mm slot die with Mac valves, 320 mm pattern and optional filter manifold. Dimensions are expressed as “mm [inch]”. Apex Slot Die Applicator, Manual #40-47, Rev. 10.16 Page 29...
ITW Dynatec Chapter 3 Description and Technical Specs Dimensions: APEX 470 mm with MAC Valves Applicator shown is a 470 mm slot die with Mac valves, 420 mm pattern and optional filter manifold. Dimensions are expressed as “mm [inch]”. Page 30 Apex Slot Die Applicator, Manual #40-47, Rev.
Chapter 4 ITW Dynatec Installation & Setting-up Operation Chapter 4 Installation & Setting-up Operation CAUTION • Before setting up, please read this documentation carefully. • Pay attention to all the installation and connecting advices. • Heed all safety instructions mentioned in chapter 2. 4.1 Conditions for set-up and mounting Place requirement Install the APEX Applicator in the machine so that the operator is able to work on it from...
ITW Dynatec Chapter 4 Installation & Setting-up Operation 4.2 Installation Typical Installation CAUTION • All work on or with this unit is only permitted for skilled personnel! • Pay attention to the electrical schematics! • Clean and dry air to the applicator solenoids is required. •...
Page 33
Chapter 4 ITW Dynatec Installation & Setting-up Operation Three Hose Inlets on Service Block Four Hose Inlets on Service Block Inlet Top Inlet Inlet Side Side Inlet Inlet Bottom Inlet Service Block Inlet Filter Block 3. Make the electrical connection as follows: Make the connection from the hose to the applicator by connecting the female connector of the hose to the male connector of the applicator.
ITW Dynatec Chapter 4 Installation & Setting-up Operation Off-roll Installation Notes on Proper Off-roll Installation: • Support the web (as the two rollers are supporting it in the illustration below) within a few inches of each side of the slot nozzle. •...
Chapter 4 ITW Dynatec Installation & Setting-up Operation Installation of Optional Wing Assemblies Wing assemblies are attached to either side of an Apex applicator in order to give additional stability to a moving substrate. Two wing assemblies are required per application, either a right and left pair, or two universal wing assemblies.
ITW Dynatec Chapter 4 Installation & Setting-up Operation 4.3 Quality of compressed Air Compressed air quality class according to ISO 8573-1 • We recommend to use a maintenance-unit for compressed-air conditioning with a filter 40µm. • Keep the quality class 5.4.2 according to ISO 8573-1. Classification of Quality Classes According to ISO 8573-1: Class 1.
Chapter 4 ITW Dynatec Installation & Setting-up Operation 4.4 Advices for the setting-up operation WARNING Start with set-up operation not until • the functioning of the unit is known, and • the unit installation for setting-up operation has been done according to the details given in the previous chapter.
ITW Dynatec Chapter 4 Installation & Setting-up Operation Risk of stumbling on cables and heated hoses! Keep your hands away from running parts of the unit (pumps, motors, rolls or others). 4.5 Setting-up operation, in general This is a generic start-up and purging process: 1.
Page 39
Chapter 4 ITW Dynatec Installation & Setting-up Operation 6. Adjust the adhesive pressure by the pressure regulator. 7. Place a heat resistant container under the applicator to collect the material that drains from it. WARNING HIGH PRESSURE RISK OF BURNS AND INJURY! •...
ITW Dynatec Chapter 4 Installation & Setting-up Operation 16. Start the unit (web material). Make sure that the material web runs even. 17. Activate the module solenoids for the adhesive application. Adhesive will be applied; the adhesive film will be formed! 18.
Chapter 5 ITW Dynatec Maintenance and Repair Notes Chapter 5 Maintenance and Repair Notes 5.1 Security advices for maintenance and repair Heed all security advices given in chapter 2. Use only original parts from ITW Dynatec, otherwise ITW Dynatec’s warranty is void! Maintenance and repair work is only permitted for skilled personnel! Always wear safety shoes, heat-resistant protective gloves, safety goggles and protective clothing that cover all vulnerable parts of the body while...
ITW Dynatec Chapter 5 Maintenance and Repair Notes Equipment Preparation for Maintenance & Repair • Adhesive processing equipment must be worked on while hot enough to soften any material residue within the assembly. This depends on the type of adhesive used with the equipment.
Chapter 5 ITW Dynatec Maintenance and Repair Notes 5.2 Maintenance plan CAUTION Heed all security advices given in chapter 5.1. Use only original parts from ITW Dynatec, otherwise ITW Dynatec’s warranty is void! Please use only the indicated lubricants and keep the prescribed maintenance intervals. Consider in addition the enclosed regulations of manufactures.
ITW Dynatec Chapter 5 Maintenance and Repair Notes 5.3 Replacement of Module WARNING Heed all security advices given in chapter 5.1. Maintenance and repair work is only permitted for skilled personnel! Always wear safety shoes, heat-resistant protective gloves, safety goggles and protective clothing that cover all vulnerable parts of the body while working on the heated unit! Risk of injury or severe burns! During this procedure, hot adhesive can come out of the Applicator...
Chapter 5 ITW Dynatec Maintenance and Repair Notes 5.4 Replacement of the Filter in Optional Filter Block WARNING Heed all security advices given in chapter 5.1. Maintenance and repair work is only permitted for skilled personnel! Always wear safety shoes, heat-resistant protective gloves, safety goggles and protective clothing that cover all vulnerable parts of the body while working on the heated unit! Risk of injury or severe burns! During this procedure, hot adhesive can come out of the Applicator...
Page 46
ITW Dynatec Chapter 5 Maintenance and Repair Notes 21. Re-install a new filter basket and the filter nut. Tighten the filter nut until it is seated firmly, taking care not to cut the O-ring. After finishing the maintenance or repair works: ...
Chapter 5 ITW Dynatec Maintenance and Repair Notes 5.5 Shim Replacement All slot die heads are equipped with shims, located between the die plate and the die adapter of the extruder. A standard (0.005”) shim is factory-installed on your extruder. Two additional cut shims are included, along with three blank shims.
Page 48
ITW Dynatec Chapter 5 Maintenance and Repair Notes 9. Inspect the new shim for any burrs or rough edges. Using 400 grit paper on a flat surface, sand as required to insure flatness. 10. Re-attach shim and die plate to the body, keeping the screws loose. 11.
Chapter 5 ITW Dynatec Maintenance and Repair Notes 5.6 Replacement of Heater Cartridge or Sensor Terminal Block Heater Cartridge (in a Service Block port) Ground Wire RTD Sensor (located in the cable assembly) ITW Dynatec has a High Temp Heater Splice Kit available (PN 102645). Each kit contains sufficient connectors and shrink tube to replace a heater cartridge (the heater is ordered separately).
Page 50
ITW Dynatec Chapter 5 Maintenance and Repair Notes This page intentionally left blank. Page 50 Apex Slot Die Applicator, Manual #40-47, Rev. 10.16...
Chapter 6 ITW Dynatec Troubleshooting Chapter 6 Troubleshooting 6.1 Troubleshooting In General NOTE: Please re-read all security advices given in chapter 2 before performing any troubleshooting or repair procedures. All troubleshooting or repair procedures must be performed by qualified, trained technicians.
ITW Dynatec Chapter 6 Troubleshooting 6.2 Troubleshooting Guide NOTE: The temperatures measured on the outer surface may deviate significantly from the temperatures set and displayed. This can lead to a false conclusion (e.g. defective heating). Such a difference is normal and depends also largely on the materials used. Preliminary Checks: Verify the following before proceeding: •...
Page 53
Chapter 6 ITW Dynatec Troubleshooting Problem Possible Cause Solution Applicator is too hot. 1. Applicator temperature 1. Change setpoint, see ASU setpoint is too high. manual. 2. Inoperative temperature 2. Check/ replace sensor. sensor. Air escapes from module. 1. Inoperative piston O-ring. 1.
ITW Dynatec Chapter 6 Troubleshooting 6.3 Testing of Heater Cartridge or Temperature Sensor 1. Turn the ASU OFF and make sure all adhesive air pressure and the pump are turned OFF. 2. Unplug the electrical cable from the adhesive supply hose to expose the pins in the cable.
Chapter 6 ITW Dynatec Troubleshooting Testing Resistance of the RTD Temperature Sensor a. The resistance value (Ohms) of your temperature sensor depends on the temperature of the sensor at the time it is being tested. Resistance/ Voltage Tables for RTD Temperature Sensor: TC Voltage –...
Page 56
ITW Dynatec Chapter 6 Troubleshooting This page intentionally left blank. Page 56 Apex Slot Die Applicator, Manual #40-47, Rev. 10.16...
Chapter 8 ITW Dynatec Component Illustrations and Bill of Materials Chapter 8 Component Illustrations and Bill of Materials WARNING All parts must be periodically inspected and replaced if worn or broken. Failure to do this can affect equipment’s operation and can result in personal injury. This chapter contains the component illustrations (exploded-view drawings) for each assembly.
Chapter 8 ITW Dynatec Component Illustrations and Bill of Materials Typical APEX 270mm Service Block Assembly, PN 111087 Item No. Part Number Description Quantity 103347 Heater and Sensor Plate Module Assembly (Interchangeable, shown for 110427 reference only) 101625 Fitting, Plug, 1/4 BSPP, Soc, Stl 101624 Fitting, Straight, 6 JIC x 1/4 BSPP 110967...
Page 74
ITW Dynatec Chapter 8 Component Illustrations and Bill of Materials Note: Items #3 and #4 are interchangeable depending on how many inlets are required to be opened or closed. Illustration: Typical APEX 270mm Service Block Assembly, PN 111087 Page 74 Apex Slot Die Applicator, Manual #40-47, Rev.
ITW Dynatec Chapter 8 Component Illustrations and Bill of Materials APEX Slot Die Module, with MAC solenoid valve Item Part Number Description APEX Slot Die Module, Stem stroke 0.3 mm, 110427 with MAC Solenoid valve 24V 9.3W (PN 810028) APEX Slot Die Module, High-Flow, Stem stroke 0.6 mm, 814049 with MAC Solenoid valve 24V 9.3W (PN 810028) Fitting 1/8 UNI Straight Male (PN 072X529)
Chapter 8 ITW Dynatec Component Illustrations and Bill of Materials APEX Slot Die Module, with MAC solenoid valve and air tubes Item Part Number Description APEX Slot Die Module, Stem stroke 0.3 mm, 819214 with 400 series MAC Solenoid valve 24V, 4,24,1/4,JB (PN 108968) APEX Slot Die Module, Stem stroke 0.3 mm, 810821 with MAC Solenoid valve 24VDC, 4,02,1/8,HIR (PN 100054)
ITW Dynatec Chapter 8 Component Illustrations and Bill of Materials APEX Slot Die Module, (rectangle stand-off), with Festo solenoid valve Item Part Number Description APEX Slot Die Module, Stem stroke 0.3 mm, with 24 VDC Festo high-speed solenoid valve, 6mm tube fitting, 820802 (PN 115055) APEX Slot Die Module, Stem stroke 0.3 mm,...
ITW Dynatec Chapter 8 Component Illustrations and Bill of Materials Typical, Optional APEX Wing Assemblies Item No. Part Number Description Quantity 812386 Wing Assy. 25mm Left Hand 812374* Wing Assy. 25mm Right Hand 810550 Wing Assy., 50mm Universal 812108 Wing Assy., 55mm Universal An assembly consists of: 107531 Screw M4x20mm...
Chapter 8 ITW Dynatec Component Illustrations and Bill of Materials 8.1 Specific APEX Extruder Apex Slot Die Applicator, Manual #40-47, Rev. 10.16 Page 87...
Page 88
ITW Dynatec Chapter 8 Component Illustrations and Bill of Materials Page 88 Apex Slot Die Applicator, Manual #40-47, Rev. 10.16...
Chapter 9 ITW Dynatec Schematics Chapter 9 Schematics Pin Connectors & Electrical Schematics Note: Pin connectors are viewed from the exposed end. Pins not shown on schematics are not used. DynaControl/Dynamini or PLC (Platinum RTD) Control Scheme, PN 103117 Microprocessor Temperature Control (MCV) or CompuVision Control Scheme, PN 045X144 Apex Slot Die Applicator, Manual #40-47, Rev.
ITW Dynatec Chapter 9 Schematics Upgrade (Nickel RTD) Control Scheme PN 104551 NOTE: Pin out numbers are not labeled on the upgrade connector. Upgrade (J-type Thermocouple) Control Scheme Upgrade (Platinum RTD) Control Scheme Page 90 Apex Slot Die Applicator, Manual #40-47, Rev. 10.16...
Chapter 10 ITW Dynatec Appendix Chapter 10 Appendix Solenoid Valve Configurations, Schematics & Setup This Appendix covers the pneumatic setup of the solenoid valves used to actuate the adhesive modules. A coalescing filter/ regulator kit (PN 100055) is available to provide regulated, oil-free air to the solenoid valves.
ITW Dynatec Chapter 10 Appendix Section 1, 24 VDC MAC Solenoid valve, 4,02,1/8,HIR, PN 100054 Description Direct acting poppet valve, 4-way, 1/8 NPT ports, with non-locking recessed manual operator. Connections Inlet Exhaust Open side of module Close side of module Typical Setup Apply full air pressure (80-90 psi) to IN port of solenoid valve.
Chapter 10 ITW Dynatec Appendix Section 2, 24 V MAC Solenoid valve 9.3W, PN 810028 Description Direct acting poppet valve, 4-way, surface mount, with non-locking recessed manual operator. Connections Within valve. Typical Setup Apply full air pressure (80-90 psi) to IN port of solenoid valve. Use air control kit PN 100055, configured as shown below.
ITW Dynatec Chapter 10 Appendix Section 3, 24 VDC Festo high-speed solenoid valve, PN 115055 & 115056 Description Direct-acting spool valve, 4-way, 24 VDC operation with M7 ports. Solenoid valve is configured to connect directly to the module. It is not setup for use as an in-line solenoid. Connections Port 1 Inlet...