Summary of Contents for VAKI Heathro Fish

  • Page 1 Heathro Fish Pump User Manual Version: March 2014...
  • Page 2: Table Of Contents

    Heathro Fish Pump Manual Contents Warranty Terms of Heathro Fish Pump................2 Neighborhood ...............Error! Bookmark not defined. Explanation of Parts ......................4 3.1 The cochlea .........................4 3.2 Main engine.........................4 3.3 Priming motor......................4 3.4 Priming tank ........................5 3.5 Priming pump ......................5 3.6 Control cabinet ......................5 3.7 Remote Control ......................6...
  • Page 3: Warranty Terms Of Heathro Fish Pump

    Such defects will be repaired or replaced. The equipment must be returned to the manufacturer or authorized representative for the repair. VAKI offers waranty for any original parts that are used for repair for a period of one (1) year from date of delivery.
  • Page 4 Heathro Fish Pump Manual 2. Environment The Heathro Fish pump is designed to work in all weathers, except for temperatures below 0 ° C (Celsius). Use in cold weather can cause damage to hoses and priming system. Heathro pump is built on a chassis with 2 large rubber wheels that can carry up to 400 kg per wheel, this allows the pump to easily move over rough and uneven surfaces.
  • Page 5: Explanation Of Parts

    Heathro Fish Pump Manual 3. Explanation of Parts Heathro Fish pump is made of aluminum and fiberglass and provides very gentle handling of fish during transport. The pump is 6 "but can be reduced down to 4", 5 "or 3" with purpose made fish friendly cam lock reducer kits.
  • Page 6: Priming Tank

    Heathro Fish Pump Manual 3.4 Priming tank The Priming tank must be filled with water before using the pump. The water in this tank is used to create suction in the pumping system. Only after running the priming pump and when water starts flowing out the priming sytem outlet can the main motor/pump can be started.
  • Page 7: Remote Control

    Heathro Fish Pump Manual 1 Turn off the power at the main switch and open the door of the control cabinet. The door can not be opened unless the main switch is turned off. 2 Turn on the power in the cabinet by turning the white shaft of the main switch clockwise. There will now be electric current in components of the cabinet, so avoid contact with any live components.
  • Page 8: Cranes

    3.9 Connections and Reducers There are different sizes of reducers and connections with Heathro fish pump. The Camlock system is used for quick and safe connection of hoses. The standard size is 6 " and 4" but 5“and 3“ can also be ordered. The...
  • Page 9: Rubber Wheel

    4. Use of Heathro Fish Pump Heathro fish pump is available in three versions, electric, gas and hydraulic. 4.1 Electric model Before you start the fish pump. 1 Make sure the main motor and priming motor is turned off.
  • Page 10: Maintenance

    Heathro Fish Pump Manual 4.2 Maintenance After the first 24 hours of use: 1 Check the belts have proper tension Daily Maintenance: 1 Flush the pump and motor with fresh water 2 Check Camlock connections. 3 Check mechanical parts. Weekly maintenance 1 Lubricate the wheel bearing.