7.4.2 Power cable, preassembled with angled M8 plug 7.4.3 Data cable, preassembled with M12 plug 7.4.4 Data cable, preassembled with RJ45 plug 7.4.5 Straight data plug, freely configurable 7.4.6 Angled data plug, freely configurable Type code breakdown Appendix Converting units of length Part label www.balluff.com english...
BTL7-V50T-M _ _ _ _ -P-C003 Micropulse Transducer in a Profile Housing Notes to the user Validity The CE Mark verifies that our products meet the requirements of EU Directive This guide describes the construction, function and setup 2004/108/EC (EMC Directive). options for the BTL7 Micropulse Transducer with PROFINET interface.
The warnings used here contain various signal words and specifications in the technical data is ensured only when are structured as follows: using original BALLUFF accessories. Use of any other SIGNAL WORD components will void the warranty. Hazard type and source...
BTL7-V50T-M _ _ _ _ -P-C003 Micropulse Transducer in a Profile Housing Construction and function Null point End point Nominal length = BTL5-P-3800-2 Measuring range magnet Groove 3) 2xM12 40.6 11.5 11.5 ~250 ~250 Mounting clamps with insulating bushes and ISO 4762 M5x22 cylinder head screws, 1) Unusable area max.
Flashing frequency is 0.5 Hz. The signal is shown for at least 3 s. Tab. 3-2: LED 2 3.3.3 LED 3/LED 4: Link/Activity LED 3/LED 4 Status Connection Green Port open Flashing Requested by the master to identify the device Port closed Tab. 3-3: LED 3/4 www.balluff.com english...
BTL7-V50T-M _ _ _ _ -P-C003 Micropulse Transducer in a Profile Housing Installation and connection Installing the transducer Captive magnets The following must be observed when installing the NOTICE! magnet: – Avoid lateral forces. Improper installation – Connect the magnet to the machine member with a Improper installation can compromise the function of the joint rod (see Accessories on page 13).
Fig. 4-5: Dimensions and distances with BTL5-P-3800-2 magnet Fig. 4-9: Dimensions and distances with BTL5-P-4500-1 electromagnet (24 V/100 mA) The measuring range is offset by 4 mm towards the BTL plug (see Figure 4-9). Fig. 4-6: Dimensions and distances with BTL5-P-5500-2 magnet www.balluff.com english...
BTL7-V50T-M _ _ _ _ -P-C003 Micropulse Transducer in a Profile Housing Installation and connection (continued) Electrical connection The transducer is connected via a connector. The pin assignments for the respective version can be found in Table 4-3. Note the information on shielding and cable routing.
– Check the function of the position measuring system and all associated components on a regular basis. – Take the position measuring system out of operation whenever there is a malfunction. – Secure the system against unauthorized use. www.balluff.com english...
: Use in enclosed spaces and up to a height of 2000 m above sea Degree of protection per level. IEC 60529 Individual specifications as per Balluff factory standard Connector C003 (when IP 67 : The transducer must be externally connected via a limited- attached) energy circuit as defined in UL 61010-1, a low-power source as defined in...