Samsung AE RXYDEG Series Installation Manual page 41

Air to water heat pump mono outdoor unit
Table of Contents

Advertisement

Number of
Display contents
press
11
Fan RPM
Target discharge
12
temperature
13
EEV
14
Protective control
15
IPM temp.
long-1
Main Micom version
long-1 and 1 Inverter Micom version
long-1 and 2 EEPROM version
5. Key Option
Option
Input unit
Channel address
Base heater
Operation mode
Snow accumulation
prevention control
Silent mode
Energy saving mode
Incorrect handling of thermostat, safety valve or other valves may lead to tank rupture. When servicing the unit
follow instructions carefully:
WARNING
- Always turn off main power supply when water supply is being shut off.
- Test the free operation of the safety valve regularly by opening the valve ensuring the water flows freely.
- Electrical connection and all servicing of the electrical components should only be carried out by an
authorized electrician.
- Fitting and all servicing of plumbing fixtures should only be carried out by an authorized installer.
- When replacing the thermostat, safety valve or any other valve or part supplied with this unit, use only
approved parts of the same specification.
Segment 1
B
C
D
E
F
Year(Dec)
Year(Dec)
Year(Dec)
SEG1
SEG2
Main
0
0
Main
0
1
Main
0
2
Main
0
3
Main
0
4
Main
0
5
Display
Segment 2
Segment 3
1000s digit
100s digit
100s digit
10s digit
1000s digit
100s digit
Protective control
0 : No protective
control
1 : Freezing
0 : Cooling
2 : Defrosting
1 : Heating
3 : Over-load
4 : Discharge
5 : Total current
+/-
10s digit
Month(Hex)
Day(two digit)
Month(Hex)
Day(two digit)
Month(Hex)
Day(two digit)
SEG3
SEG4
A
U
Automatic address setting (default)
0
0
Manual address setting (0 to 15)
0
0
0
1
0
0
0
1
0
0
0
1
0
0
0
1
Manual Silent mode * 0.9 (-5 dB)
0
2
Manual Silent mode * 0.75 (-7 dB)
0
3
0
4
Low-noise Silent mode (default)
0
0
0
1
Units
Segment 4
10s digit
rpm
1s digit
10s digit
step
Frequency status
0 : Normal
1 : Hold
2 : Down
3 : Up_limit
4 : Down_limit
1s digit
Day(One digit)
Day(One digit)
Day(One digit)
Function of the option
Enabled (default)
Disabled
Heat Pump (default)
Heating Only
Disabled (default)
Enabled
Manual Silent mode (-3 dB)
Manual Silent mode (-3 dB)
Disabled (default)
Enabled
°C
-
°C
-
-
-
41