Outputting Read Code - Panasonic IMAGECHECKER PV230 Manual

Functions excerpt edition
Table of Contents

Advertisement

3.3.5 Outputting Read Code

For outputting read characters, select the setting from "General Output" ("ENVIRONMENT" -> "Input/Output").
You cannot set individually whether to output or not for each Code Reader checker.
The characters to be output are read characters. They are not "judged characters" like Optical Character
Recognition checker.
For 2-byte codes, the output characters get garbled.
"General Output" setting
1.
Select "ENVIRONMENT" -> "Input/Output" -> "General Output"
from the menu bar.
2
. Select "Yes" for "Output" of the port (Serial/Ethernet/SD
Card) to which strings are output.
3.
Select "General Com." or "PLC Com." in "Protocol".
4.
Select "Yes" in "Code Reader".
5.
Specify "No. of Output Characters".
Available numbers of characters are 1 to 80.
Specify the number of characters per code reader checker.
When the number of characters recognized with each Code
Reader checker has exceeded "No. of Output Characters", only
the recognized characters of the specified number from the
beginning are output.
If the content of a code is ten characters "12345abcde", only five
characters "12345" from the beginning are output when "No. of
Output Characters" is set to 5.
6.
Select "Unused Digit" from "Fill with 0" or "Comma Sep.".
If you select "Comma Sep.",
7.
Specify "Start"*,"Data Delimiter"*, "End"*.
*Available from PV230Ver.1.30.
*Available only for General Communication Protocol.
*These items are are valid if you setting "Unused Digit" to "Comma Sep."
Item
Start
Data Delimiter
End
80
procedure
No.7 will be
Description
It is added to the beginning of general result output
data.
It is added between output data as a delimiter.
It is added before the terminal CR* of general result
output data.
(* When BCC is added, it is added before BCC.)
valid.
Default
None