Montgomery Ward MX-27129A Owner's Manual And Parts List page 25

Home standby electric generating set
Table of Contents

Advertisement

instructions. Either spark plug can be used as
they fire simultaneously.
2. Remove the plug from the timing hole.
3. Start the engine and check the timing. The mark
on the flywheel should line up with the 19° BTC
mark on the cover.
4. If timing needs adjustment, loosen the mounting
screws on breaker box and move left to advance
or right to retard the timing.
5. Start engine to be sure mark on flywheel lines up
with 19 degree mark on cover.
6. Tighten all screws, replace timing plug.
Timing Procedure—Engine Not Running
1. Connect a continuity test lamp set across the
ignition breaker points. Touch one test prod to
the breaker box terminal to which the coil lead is
connected and touch the other test prod to a
good ground on the engine.
2. Turn crankshaft against rotation (counterclock-
wise) until the points close. Then slowly turn the
crankshaft with rotation (clockwise).
3. The lamp should go out just as the points break
which is the time at which ignition occurs (19°
BTC).
4. If timing needs adjustment, loosen the mounting
screws on the breaker box and move left to
advance or right to retard the timing.
23