Greenheck DFD Series Installation, Operation And Maintenance Manual page 78

Curtain fire dampers
Table of Contents

Advertisement

Table of Contents
Receiving, Unpacking, Handling, Storage . . . . . . . . 2
Inspection and Maintenance During Storage . . . . . . 2
Removing from Storage . . . . . . . . . . . . . . . . . . . . . . 2
Dimensional Data
Direct Drive - Fan and Optional Filter . . . . . . . . . . . 3
Belt Drive - Fan and Optional Filter . . . . . . . . . . . . 4
Mounting - Horizontal or Base Mount . . . . . . . . . . . 5
Mounting - Duct or Side Discharge . . . . . . . . . . . . . 6
Isolator Information . . . . . . . . . . . . . . . . . . . . . . . . . 6
Pre Start-Up Checks . . . . . . . . . . . . . . . . . . . . . . . . 7-8
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Tapered Bushing Hub Installation & Removal . . 9-10
Recommended Bearing Lubrication . . . . . . . . . . . 10
Parts Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12
Our Commitment . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Receiving
Upon receiving the product check to ensure all items
are accounted for by referencing the delivery receipt or
packing list. Inspect each crate or carton for shipping
damage before accepting delivery. Alert the carrier
of any damage detected. The customer will make
a notation of damage (or shortage of items) on the
delivery receipt and all copies of the bill of lading which
is countersigned by the delivering carrier. If damaged,
immediately contact your local representative. Any
physical damage to the unit after acceptance is not the
responsibility of the manufacturer.
Unpacking
Verify that all required parts and the correct quantity
of each item have been received. If any items are
missing, report shortages to your local representative to
arrange for obtaining missing parts. Sometimes it is not
possible that all items for the unit be shipped together
due to availability of transportation and truck space.
Confirmation of shipment(s) must be limited to only
items on the bill of lading.
Handling
Move fan to desired location and determine position of
access panels, discharge and motor. Make sure the inlet
and outlet have at least 2½ times the wheel diameter
(duct diameter) before any obstructions like an elbow
or transition. Attach the fan to a suitable framework
as specified; hanging or base vibration isolators are
recommended. See corresponding Fan Dimensions
tables; pages 3 and 4 for physical dimensions. Mounting
dimensions and vibration isolator centerline information
is provided on pages 5 and 6. The motor's amperage
and voltage ratings must be checked for compatibility
to supply voltage prior to final electrical connection.
Electrical lead-in wires are then connected to the factory
supplied safety disconnect switch. All wiring must
conform to local and national codes.
2
Centrifugal Inline Fans
Storage
Fans are protected against damage during shipment. If
the unit cannot be installed and operated immediately,
precautions need to be taken to prevent deterioration of
the unit during storage. The user assumes responsibility
of the fan and accessories while in storage. The
manufacturer will not be responsible for damage during
storage. These suggestions are provided solely as a
convenience to the user.
Indoor Storage: The ideal environment for the storage
of fans and accessories is indoors, above grade, in a
low humidity atmosphere which is sealed to prevent
the entry of blowing dust, rain or snow. Temperatures
should be evenly maintained between 30° to 110°F
(-1° to 43°C) (wide temperature swings may cause
condensation and "sweating" of metal parts). All
accessories must be stored indoors in a clean, dry
atmosphere.
Remove any accumulations of dirt, water, ice or snow
and wipe dry before moving to indoor storage. To avoid
"sweating" of metal parts allow cold parts to reach room
temperature. To dry parts and packages, use a portable
electric heater to get rid of any moisture buildup. Leave
coverings loose to permit air circulation and to allow for
periodic inspection.
The unit should be stored at least 3½ inches (89 mm)
off the floor on wooden blocks covered with moisture
proof paper or polyethylene sheathing. Aisles between
parts and along all walls should be provided to permit
air circulation and space for inspection.
Inspection & Maintenance During Storage
While in storage, inspect fans once per month. Keep a
record of inspection and maintenance performed.
If moisture or dirt accumulations are found on parts,
the source should be located and eliminated. At each
inspection, rotate the wheel by hand ten to fifteen
revolutions to distribute lubricant on motor. If paint
deterioration begins, consideration should be given to
touch-up or repainting. Fans with special coatings may
require special techniques for touch-up or repair.
Machined parts coated with rust preventive should be
restored to good condition promptly if signs of rust
occur. Immediately remove the original rust preventive
coating with petroleum solvent and clean with lint-free
cloths. Polish any remaining rust from surface with
crocus cloth or fine emery paper and oil. Do not destroy
the continuity of the surfaces. Thoroughly wipe clean
®
with Tectyl
506 (Ashland Inc.) or the equivalent. For
hard to reach internal surfaces or for occasional use,
®
consider using Tectyl
511M Rust Preventive, WD-40
or the equivalent.
Removing From Storage
As fans are removed from storage to be installed in their
final location, they should be protected and maintained
in a similar fashion until the fan equipment goes into
operation.
®
®