These instructions apply to 1
must be horizontal) and 2) concrete floors. Specific requirements in these instructions are mandatory. Dampers must
be installed in accordance with these instructions to meet the requirements of UL 555.
Note: Fire dampers are manufactured and labeled for either vertical or horizontal installation. The dampers must be
installed in accordance with labeling.
Receiving and Handling
Upon receiving dampers, check for both obvious
and hidden damage. If damage is found, record all
necessary information on the bill of lading and file
a claim with the final carrier. Check to be sure that
all parts of the shipment, including accessories, are
accounted for.
Dampers must be kept dry and clean. Indoor storage
and protection from dirt, dust and the weather is
highly recommended. Do not store at temperatures in
excess of 100°F (38°C).
Safety Warning
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury
or death. Read the installation, operating, and
maintenance instructions thoroughly before installing
or servicing this equipment.
This manual is the property of the owner and is required for future maintenance. Please leave it with the owner when
the job is complete.
and 3 hour rated fire dampers mounted in: 1) masonry, block, or stud walls (blades
1
2
DFD, DFD-150X, FD, FD-150X, SSDFD, SSFD, AND KFD Series

Table of Contents

General Information ...................................... 2
Pre-Installation Guidelines ............................ 2
Installation ................................................3-11
• Preparation of Openings ........................ 3
• Maximum Assembly Tables .................... 5
• Duct to Sleeve Connection ................9-10
Transfer Opening .................................. 11
Maintenance ............................................... 11
Troubleshooting .......................................... 11