INSTALLATION AND MAINTENANCE INSTRUCTIONS
Zonecheck Keyswitch
ZCK-1, ZCK-1E
Electrical Specifications
Key Switch Operating Voltage
Key Switch Mounting Options
Key Switch Operation Modes
Key Switch LED Operation
WIRING DIAGRAM FOR STAND ALONE APPLICATION
TO EARTH GND.
OR ATTACH TO
JUNCTION BOX
GND
AC
AC
PUMP
PUMP
}
WF INPUT
}
INTER-CONNECT
WATERFLOW
DETECTOR
PUMP
NOTE:
WF INPUT NOT REQUIRED FOR
KEYSWITCH OPERATION IF WATERFLOW
DETECTOR IS CONNECTED TO PANEL
OR OTHER MONITORING DEVICE.
AC POWER AND PUMP WIRING
MUST CONFORM TO NEC OR
YOUR LOCAL CODES.
D770-31-00
ZCK-1: 110V, 60 Hz; ZCK-1E: 220V, 50 Hz
Includes back box for surface or flush mounting.
For pre-wiring, use a 4-11/16" x 4-11/16" back box
Self-test: Wired locally
Group test: Interconnected
Ready state: No LED
Test initiation: Green LED
Flow switch activation: Red LED
AC GROUND
AC POWER
1
3825 Ohio Avenue, St. Charles, Illinois 60174
FOR INTERCONNECTING MULTIPLE ZONECHECK UNITS
}
WF INPUT
}
INTER-CONNECT
PUMP
}
WF INPUT
}
INTER-CONNECT
PUMP
TO NEXT
ZONECHECK
SWITCH FOR
INTERCONNECT
A Division of Pittway
1-800-SENSOR2, FAX: 630-377-6495
www.systemsensor.com
TO EARTH GND.
OR ATTACH TO
AC GROUND
JUNCTION BOX
GND
AC
AC POWER
AC
PUMP
PUMP
WATERFLOW
DETECTOR
TO EARTH GND.
OR ATTACH TO
AC GROUND
JUNCTION BOX
GND
AC
AC POWER
AC
PUMP
PUMP
WATERFLOW
DETECTOR
I56-1610-001
©
2000 System Sensor

Advertisement

loading
Need help?

Need help?

Do you have a question about the Zonecheck Keyswitch ZCK-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for System Sensor Zonecheck Keyswitch ZCK-1

  • Page 1 KEYSWITCH OPERATION IF WATERFLOW INTER-CONNECT DETECTOR IS CONNECTED TO PANEL OR OTHER MONITORING DEVICE. AC POWER AND PUMP WIRING MUST CONFORM TO NEC OR WATERFLOW YOUR LOCAL CODES. DETECTOR PUMP TO NEXT ZONECHECK SWITCH FOR INTERCONNECT D770-31-00 I56-1610-001 © 2000 System Sensor...
  • Page 2 Please refer to insert for the Limitations of Fire Alarm Systems Three-Year Limited Warranty System Sensor warrants its enclosed keyswitch to be free from defects in ment, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Please materials and workmanship under normal use and service for a period of include a note describing the malfunction and suspected cause of failure.

This manual is also suitable for:

Zonecheck keyswitch zck-1e