This guide is for quick reference only
To view the full manual, please scan this QR code
using your smarphone or visit the product page at
www.dimplex.co.uk
Energy Related Product Directive
This product complies with Lot20 of the Energy Efficiency Directive (2015/1188)
Type of heat output/ room temperature control
With electronic room temperature control
Electronic room temperature control plus week
timer
With open window detection
With adaptive start control
Model Identifier(s):
Nominal heat
Pnom
output
Height (mm)
Width (mm)
Depth (mm)
Minimum heat
Pmin
output (indicative)
Maximum continu-
Pmax-
ous heat output
,c
Auxiliary electricity Consumption
At nominal heat
elmax
output
At minimum heat
elmin
output
In standby mode
elSB
With open window detection
With adaptive start control
General Information
Please read the instructions closely before first using the product.
This heater may be used wall-mounted or freestanding. The necessary wall
mounting brackets are provided with the product as a standard. The feet screws
can be bought seperately as an accessory.
It should only be operated when in the upright position as shown - see Fig.1a and
Fig.1b. All models are splash proof to IPX0. Before connecting the heater check
that the supply voltage is the same as that stated on the heater.
Wall Mounting
IMPORTANT - The radiator must only be mounted using the kit
supplied
WARNING - This product is heavy and care should be taken in
installation
Select a suitable position on a wall, near to a mains power outlet. The radiator
should not be mounted closer than 75mm from the floor - see Fig. 2 (to enable
cleaning), or adjacent side walls. Ensure at least 305mm clear space between
the radiator and any overhanging shelf. It should not be mounted closer than 1
metre from the ceiling.
Yes
Yes
Yes
Yes
B075E
C100E
D150E
0.75 kW
1 kW
1.25 kW
659
659
659
570
840
1105
50
50
50
0.75 kW
1.00 kW
1.25 kW
0.75 kW
1.00 kW
1.25 kW
0.00
0.00
0.00
0.00
0.00
0.00
<0.0005
<0.0005
<0.0005
Yes
Yes
STEP 1: Check that you have all the necessary components:
(a) 2 x Bottom Wall brackets
(b) 2 x Top Wall Brackets
(c) 2 x Radiator Securing Brackets
(d) 2 x Screws Self-tapping.
STEP 2: Using a straight edge, draw a horizontal line (see 'Y' in Fig. 2) for the
bottom brackets at the required mounting height from the floor.
NOTE - The bottom of the radiator must not be less than 75mm
from the fllor. To achieve thism the top edge of the bottom
brackets must be at least 160mm from the floor - see Fig 2. On
this line, mark off the fixing centres according to model - see 'C'
in the table in Fig. 2 and Fig.3
Place the bottom brackets centrally over these centres with the top row of holes
on the line, and mark the fixing hole positions – see Fig. 3.
STEP 3: Drill the holes and fit wall plugs. Screw the bottom brackets in
position
E200E
– see Fig. 3.
1.5 kW
STEP 4: Measure dimension D in Fig. 2 according to model, from the top of the
659
bottom brackets and draw a horizontal line. Mark off the fixing centres
1373
for the top brackets in line with the bottom brackets. Place each top
50
bracket on the line and mark the fixing holes – see Fig. 4. Drill and plug
the wall and fix the top brackets in place.
1.5 kW
STEP 5: Place the radiator on the bottom brackets, then fit each securing bracket
1.5 kW
to the top of the radiator and secure it with the self-tapping screw
provided – see Fig. 5.
0.00
Check that the radiator is securely fixed to the wall.
0.00
<0.0005
'Y'
'C'
75
75
mm
mm
(min)
(min)
Fig. 4
Fig. 2
Fig. 3
Fig. 5
93
mm
67
mm

Advertisement

loading

This manual is also suitable for:

Ipx0B075eC100eD150eE200e