Specification
B.2.3. SeaPrince Acoustic Properties
Operating frequency
Beamwidth
Maximum range
Minimum range
B.2.4. SeaPrince Display Characteristics
Mechanical resolutions
Scanned sector
Continuous 360°
Sector offset mode
B.2.5. SeaPrince Electrical and Communication
Power requirement
Communication
Protocols
Data rate
Drive capability
(ARCNET only)
Isolation
(ARCNET only)
0374-SOM-00001, Issue: 08
Maximum bandwidth 500kHz to 900kHz (default of 675kHz)
38° vertical, 2.3° horizontal
100m
1m
0.45°, 0.9°, 1.8°, 3.6°
360°
Yes
Yes
12 to 36V DC at 10W (18 to 56V DC optional)
ARCNET, RS232, RS485
ARCNET: 156kbit·s
(maximum)
-1
RS232 & RS485: 115.2kBd (maximum)
1500m at 156kbit·s
-1
2500m at 78kbit·s
-1
Transformer Isolated 1500V
44
SeaKing & SeaPrince Imaging Sonars
© Tritech International Ltd.