Summary of Contents for socomec DIRIS A14

  • Page 1 DIRIS A14 Multifunction measuring unit - PMD with MID certification www.socomec.com/ en/diris-a14 www.socomec.com...
  • Page 2: Table Of Contents

    ........... .30 DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 3: Documentation

    1. DOCUMENTATION All documentation on the DIRIS A14 is available on the website at the following address: www.socomec.com/en/diris-a14 DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 4: Risks And Warnings

    The term "device" used in the paragraphs below refers to the DIRIS A14. This equipment may only be installed, used, serviced and maintained by trained, qualified professionals. Failure to comply with the instructions in this manual will invalidate SOCOMEC's liability. 2.1. Risk of electrocution, burns or explosion •...
  • Page 5: Preliminary Operations

    • the device reference number is the same as on your order, • The package includes: - 1 product - 1 sealing kit (ref. 4850 304U) - 1 line resistor (ref. 4899 0019) - 1 Quick start DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 6: Introduction

    2. Access to energies and programming validation. 3. Access to programming menu. 4. Access to electrical parameters and power levels. 5. Metrological LED on active energy - 0.1Wh / impulse 6. Information relating to MID certification. 4.4. Dimensions DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 7: Measured Electrical Dimensions

    Energy consumption Ea+ day, total n.a. kWh and 10Wh week, month, n and n-1 Where Ti= Ea+ of tariff i, i=1 - 4; the tariff is selected by the communication bus. n.a. = not available. DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 8: Installation

    Fitting the rail accessory to the device Installing the fitted device onto the external plate Clipping to the back of the device: no tools required Clipping the set onto the external plate: no tools required DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 9: Connection

    6.1. DIRIS A14 connection rigid 1.5 mm -> 10 mm flexible 1 mm -> 6 mm 12 mm Posidriv PZ2 1.5 Nm Communication terminal block LIYCY-CY NC: not connected. May be used for shielding continuity. DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 10: Connecting To The Electrical Network And To Loads

    3P+N – 3CT 3P - 3CT RS485 RS485 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 COM - RS485 COM - RS485 DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 11 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 COM - RS485 COM - RS485 Fuse: 0.5 A gG / 0.5 A class CC V1 V2 V3 VN V1 V2 V3 VN DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 12: Mid Compliance

    • RS485 communication The information provided via the RS485 COM is transmitted for information only and has no legal value. • Declaration of MID conformity The MID declaration of conformity is available on the website: www.socomec.fr Fig.1 Fig.2 DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 13: Communication

    If the distance of 1200 m is exceeded and/or the number of products is greater than 32, a repeater must be added to enable additional products to be connected. A 120 Ohm resistor must be fixed at both ends of the connection. DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 14: Communication Structure

    Note: The response time (question/ response time out) is no more than 250 ms. 8.4. Communication tables The communication tables and the associated explanations are available on the DIRIS A14 documentation page on the website at the following address: www.socomec.com/en/diris-a14 XX = default value DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 15: Configuration

    Modifies the current screen parameters Validates the modification Exit programming mode (press PROG for 3 seconds) Note: after 120 seconds of inactivity, the device exits programming mode without saving the changes (except for a reset). DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 16: Example: Configuring The Choice Of Current Transformer

    (50) x14 (300) x23 (1250) x6 (60) x15 (400) x24 (1500) x7 (75) x16 (500) x25 (1600) x8 (100) x17 (600) x26 (2000) x9 (125) x18 (700) x27 (2500) ▼ XX = default value DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 17: Overall View Of The Programming Menu

    Communication parity Communication stop bit Reset the max. and partial energy values to zero: Max. 4I, Max. P, Max. Q, Max. S, Max. cosj, Partial Ea+, Partial Er+, Partial Ea-, Partial Er- Return to the first programming menu screen DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 18: Detailed View Of The Programming Menu

    4800, 9600, 19200, 38400 Communication parity no, odd, even Communication stop bit 1, 2 Reset energies Max. 4I, Max. P, Max. Q, Max. S, Max. cosj, Partial Ea+, Partial Er+, Partial Ea-, Partial Er- Return to the first programming menu screen DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 19: Use

    ______________ Min. three-phase active, reactive and apparent powers ______________ Instantaneous three-phase cosj ______________ Max. three-phase cosj ______________ Min. three-phase cosj ______________ Return to the first measuring menu screen DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 20: Detailed View Of The Energy Menu

    Total imported reactive energy Total exported active energy Total exported reactive energy Partial imported active energy Partial imported reactive energy Partial exported active energy Partial exported reactive energy Return to the first energy menu screen DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 21: Detailed View Of The Measurement Menu

    (L1, L2, L3) Instantaneous three-phase active power Instantaneous three-phase cosj Instantaneous three-phase reactive power Max. three-phase cosj Instantaneous three-phase apparent power Min. three-phase cosj Max. three-phase active power Return to the first measuring menu screen DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 22: Connection Test Function

    Press "E" for 3 seconds. The error message appears on the screen. If there is more than one error, they are displayed one after the other. The messages below indicate the connection status of the phases on the DIRIS A14. Message list...
  • Page 23: Assistance

    Check the connection. Start the connection test function (see "11. Connection test function", page 22). Power levels and power factors (Cosj) Check the connection. Start the connection test function incorrect (see "11. Connection test function", page 22). DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 24: Features

    COSjPOWER FACTOR MEASUREMENT Measurement range ±0.01 - ±1 Accuracy Measurement refresh period ENERGY MEASUREMENT Active Reactive Total and partial reading Yes (0.01 - 99999.99 kWh / MWh / kvarh / Mvarh) Bi-directional reading (Ea+, Ea- et Er+, Er-) DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 25 (1) Voltages must be balanced in a 3NBL network. (2) Functions only available via the communication system. The full list of these functions is set out in the modbus communication table which can be downloaded from the website at www.socomec.com. DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 26: Performance Classes

    Fn=60Hz - rows 1 - 52 THDi* Total harmonic current distortion rate (compared Fn=50Hz - rows 1 - 63 with the fundamental rate) Fn=60Hz - rows 1 - 52 * functions only available via modbus communication. DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 27: List Of Abbreviations

    Harmonic phase-to-neutral voltage distortion rate Communication Slave address Communication speed in bauds (bits per second) Communication frame parity No parity Even Even parity Odd parity Stop Frame stop bit 1 stop bit 2 stop bits DIRIS A14 - 542 957 A - SOCOMEC...
  • Page 28 542 957 A - EN - 11/14...