Drive carrier
Disk drives
Midplane
Storage processor
Power supply module
Cache Protection Module
Midplane
Storage processor (SP)
Power supply module
Cache Protection Module (single SP configuration only)
EMI shielding
Disk drive carriers are plastic assemblies that provide smooth, reliable contact with the
enclosure slot guides and midplane connectors. Each carrier has a handle with a latch and
spring clips. The latch holds the disk drive in place to ensure proper connection with the
midplane. The
"Front view"
integrated into the chassis that the carrier is in. These LEDs primarily show the disk drive
readiness as well as activity.
You can visually distinguish between drive types by their different latch and handle
mechanisms and by the type, capacity, and speed labels on each drive. You can add or
remove a disk drive while the DPE is powered up, but you should exercise special care
when removing drives while they are in use. Disk drives are extremely sensitive electronic
components. For more information about the supported disk drives for the VNXe3100,
®
EMC
VNXe™ Series Storage Systems Disk and OE Matrix
refer to the
A midplane separates the front-facing disk drives from the rear-facing SPs. It distributes
power and signals to all components in the enclosure. SPs and disk drives plug directly
into the midplane.
The storage processor (SP) is the intelligent component of the disk processor enclosure
(DPE). Basically, it acts as the control center. Each SP includes status LEDs, an I/O
personality module, LAN ports, and so on. Two latches on the SP lock it into place to
ensure proper connection. The
the location and description of the connectors and LEDs.
When viewed from the rear, the power supply module is located on the top, left and right
of the DPE. This module is an auto-ranging, power-factor-corrected, multi-output, off-line
converter with its own line cord. Each power supply module includes status LEDs. A latch
on the power supply module locks it into place to ensure proper connection. The
power supply/cooling module"
location and description of the connectors and LEDs.
In a single SP configuration, the Cache Protection Module provides mirrored VNXe
Operating Environment (OE) cache memory that is not possible with a single SP. The Cache
Protection Module capacity is 1 GB.
section on
page 16
shows the disk drive ready LEDs that are
"SP"
section on
page 19
section on
page 21
provides more information about the
document.
provides more information about
System component description
Overview
"AC
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emc vnxe3100

Table of Contents