Siemens GMA 1 Series Mounting Instructions page 9

Rotary-type spring return actuator
Hide thumbs Also See for GMA 1 Series:

Advertisement

Switch A
(S1)
辅助开关 A
Voltage
스위치 A
スイッチA
AC 24 V
AC 24 V
L1 (phase)
L2
AC 230 V
L3
L
(phase)
X
AC 24 V
mixed
AC 230 V
de
Kabelbezeichnungen
en
Wire designations
Siemens Building Technologies
Switch B
(S4)
ok /
辅助开关 B
no!
스위치 B
スイッチB
AC 24 V
ok
L1 (phase)
ok
L2
ok
ok
L3
no!
≠ L
(phase)
X
AC 230 V
no!
AC 24 V
no!
Anschluss
Code Nr.
Farbe
Antriebe
G
1
rot
AC 24 V
G0
2
schwarz
DC 24...48 V
Y1
6
violett
Y2
7
orange
Y
8
grau
U
9
rosa
Antriebe
L
3
braun
AC 230 V
N
4
blau
Hilfsschalter
Q11
S1
grau/rot
Q12
S2
grau/blau
Q14
S3
grau/rosa
Q21
S4
schwarz/rot
Q22
S5
schwarz/blau
Q24
S6
schwarz/rosa
Rückführ-
a
P1
weiss/rot
potentiometer
b
P2
weiss/blau
c
P3
weiss/rosa
Connection
Code No. Color
Actuators
G
1
red
AC 24 V
G0
2
black
DC 24...48 V
Y1
6
purple
Y2
7
orange
Y
8
grey
U
9
pink
Actuators
L
3
brown
AC 230 V
N
4
blue
Auxiliary
Q11
S1
grey/red
switch
Q12
S2
grey/blue
Q14
S3
grey/pink
Q21
S4
black/red
Q22
S5
black/blue
Q24
S6
black/pink
Feedback
a
P1
white/red
potentiometer
b
P2
white/blue
c
P3
white/pink
Ader 9 (U) bis max. 41 V geschützt gegen Falschverdrahtung
Wire 9 (U) up to max. 41 V protected against faulty wiring.
La borne 9 (U) est protégée contre une erreur de branchement jusqu'à
41 V max.
Ledare 9 (U) är upp till 41 V skyddad mot felkoppling.
Ader 9 (U) tot max. 41 V beveiligd tegen foutieve bedrading.
Cavo 9 (U) fino a 41 V protetto contro errori di cablaggio.
Johdin 9 (U) on suojattu väärältä johdotukselta (maks. 41 V).
Cable 9 (U) hasta un máx. de 41 V protegido contra fallos de cableado.
Leder 9 (U) indtil max. 41 V beskyttet mod fejlkobling.
9 (U) 端子最高电压负荷为41伏以在接线错误时保护电路版。
9 (U) 번 단자는 오결선시에 최대41V까지 보호 된다.
配線 9 (U) の異電圧保護は、max.41 Vまで
Kabel
Bedeutung
Akürzung
RD
System Potential AC 24 V / DC 24...48 V
BK
Systemnull
VT
Stellsignal AC 0 V, AC 24 V / DC 24...48 V, "öffnen"
OG
Stellsignal AC 0 V, AC 24 V / DC 24...48 V, "schliessen"
GY
Stellsignal DC 0...10 V, 0...35 V
PK
Stellungsanzeige DC 0...10 V
BN
Phase AC 230 V
BU
Nullleiter
GYRD
Schalter A Eingang
GYBU
Schalter A Ruhekontakt
GYPK
Schalter A Schliesskontakt
BKRD
Schalter B Eingang
BKBU
Schalter B Ruhekontakt
BKPK
Schalter B Schliesskontakt
WHRD
Potentiometer 0...100 % (P1-P2)
WHBU
Potentiometer Abgriff
WHPK
Potentiometer 100...0 % (P3-P2)
Cable
Meaning
Abbreviation
RD
System potential AC 24 V / DC 24...48 V
BK
System neutral
VT
Pos. signal AC 0 V, AC 24 V / DC 24...48 V, "open"
OG
Pos. signal AC 0 V, AC 24 V / DC 24...48 V,"close"
GY
Pos. signal DC 0...10 V, 0...35 V
PK
Position indication DC 0...10 V
BN
Line AC 230 V
BU
Neutral
GYRD
Switch A input
GYBU
Switch A normally-closed contact
GYPK
Switch A normally-open contact
BKRD
Switch B input
BKBU
Switch B normally-closed contact
BKPK
Switch B normally-open contact
WHRD
Potentiometer 0...100 % (P1-P2)
WHBU
Potentiometer pick-off
WHPK
Potentiometer 100...0 % (P3-P2)
74 319 0333 0 e
M4614
10-01-2013
9 / 12