Symptom
Machine refuses to start
Fluctuating pressure
Machine stops
Machine pulsating
Machine starts, but no water
comes out
www.PyleUSA.com
Cause
Machine not plugged in
Defective socket
Fuse has blown
Defective extension cord
Pump sucking air
Valves dirty, worn out or stuck
Pump seals worn out
Incorrect main voltage
Thermal sensor activated
Nozzle partially blocked
Air in inlet hose
Inadequate supply of water
Nozzle partially blocked
Water filter blocked
Hose kinked
Pump/hoses or accessory frozen
No water supply
Water filter blocked /Nozzle
blocked
Recommended action
Plug in machine
Try another socket.
Replace fuse. Switch off
other machines.
Try without the extension
cord.
Check the hoses and
connections are airtight.
Clean and replace valves
or refer to local distributor
Check that the main
voltage corresponds to
specification on the model
tag.Leave the washer for 5
minutes to cool down.
Clean the nozzle
Allow machine to run with
open trigger until regular
working pressure resumes.
Check that the water supply
corresponds to specifica-
tions required
NB! Avoid using long, thin
hoses (min. 1/2").Clean the
nozzle /Clean the filter
Straighten out hose.
Wait for pump/hoses or
accessory to thaw.
Connect inlet water.
Clean the filter /Clean
the nozzle