RS-232C Configurations

7-Wire Configuration
(Serial female-female NULL modem cable)
PC
RXD
2
TXD
3
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
3-Wire Configurations (Not standard)
PC
RXD
2
TXD
3
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
TV
3
TXD
2
RXD
5
GND
6
DSR
4
DTR
8
CTS
7
RTS
D-Sub 9
TV
3
TXD
2
RXD
5
GND
6
DSR
4
DTR
8
CTS
7
RTS
D-Sub 9
Set ID
Set ID number; Real Data Mapping
1
Press SETTINGS to access the main menus.
2
Press the navigation buttons to scroll to
OPTION and press OK.
3
Press the navigation buttons to scroll to Set
ID and press OK.
4
Scroll left or right to select a set ID number
and select CLOSE. The adjustment range is
1-99.
5
When you are finished, press EXIT.
*Real data mapping
0 : Step 0
A : Step 10 (SET ID 10)
F : Step 15 (SET ID 15)
10 : Step 16 (SET ID 16)
63 : Step 99 (SET ID 99)
64 : Step 100