SUN2000-(12KTL, 15KTL, 17KTL, 20KTL)-M0
User Manual

4.3.2 Space Requirements

Installation Angle Requirements
The SUN2000 can be wall-mounted or pole-mounted. The installation angle
requirements are as follows:
Figure 4-1 Installation tilts
Installation Space Requirements
Issue 06 (2020-07-02)
The SUN2000 is heavy. Ensure that the installation surface is solid enough to
bear the weight load.
In residential areas, do not install the SUN2000 on drywalls or walls made of
similar materials which have a weak sound insulation performance because
the noise generated by the SUN2000 is noticeable.
Install the SUN2000 vertically or at a maximum back tilt of 15 degrees to
facilitate heat dissipation.
Do not install the SUN2000 at forward tilted, excessive back tilted, side tilted,
horizontal, or upside down positions.
Reserve enough space around the SUN2000 to ensure sufficient space for
installation and heat dissipation.
Copyright © Huawei Technologies Co., Ltd.
4 Installation
20