Installation procedure
October 2019
hydraulic bolt tensioning equipment will specify number of exposed threads outside the
nut.
Do not use damaged or worn stud bolts or nuts.
Do not use nuts or stud bolts that do not fit together correctly.
Do not use nuts or stud bolts without grade or type identification.
Do not mix nuts or stud bolts of different coatings. Different nut and stud bolt coatings
require different torques to achieve the same bolt tension.
Do not assemble nuts with the identification hard stamp against the back face of the
flange
Stud bolt and nut storage
Remove each nut and bolt as a pair. Thread the matching nut back onto the bolt. Stack
them in a fashion that will not cause thread damage.
Reuse of stud bolts and nuts
The reuse of threaded fasteners is permitted on Daniel control valves under the following
conditions:
Fasteners are clean, free of corrosion, paint, thread damage, cracks, teeth marks
(caused by wrenches) or other signs of damage.
Fasteners are not tightened to or beyond their yield strength.
Fasteners have not lost their coating.
Compare the threads of a used stud bolt with the thread of a new stud bolt. Finger-tighten
the nut over the entire thread length of the bolt.
68