Download Print this page

Honeywell FocusPRO TH6110D Manual page 14

Hide thumbs Also See for FocusPRO TH6110D:

Advertisement

Installation
Guide
[f you
have
di[Yiculty
with
your
thermostat,
please
try the
suggestions
below.
Most
problems
can be corrected
quickly and easily:
Display is blank
*
Check circuit breaker and reset if necessary.
.
Make sure power switch
at heating & cooling system
is on.
Make sure furnace door is closed securely.
if thermostat
is battery
powered,
make sure fresh AA alkaline batteries
are correctly
installed (see page 7).
Temperature
se_ings
de not
change
Make sure heating and cooling
temperatures
are set to acceptable
ranges:
Heat: 40 ° to 90°F (4.5 ° to 32°C).
.
Cool: 50 ° to 99°F (10 ° to 37°C).
Heating system
does not respond
("Heat On"
appears on
SCan)
Cooling system
does not respond
("Cool On"
appears on
SCan)
Fan does not
turn on in a car
for heat
Heat pump
issues coel air
in heat mode_
Or
warm
air
in
cool mode
HeatJcool both
On at
same
time_
or heat does
not turn
off
o
Check for 24 Vac at the equipment
on the secondary
side of the trans-
former between
power and common,
if voltage
is not present, check the
heating equipment
to find the cause of the problem.
Check for 24 Vac between the heat terminal (VV) and the transformer
common,
if 24 Vac is present, the thermostat
is functional.
Check the
heating equipment
to find the cause of the problem.
o
Check for loose or broken wires between
the thermostat
and the heating
equipment.
o
Check for 24 Vac at the equipment
on the secondary
side of the trans-
former between
power and common,
if voltage
is not present, check the
cooling equipment
to find the cause of the problem
Check for 24 Vac between the cooling terminal
(Y) and the transformer
common,
if 24 Vac is present, the thermostat
is functional.
Check the
cooling system to find the cause of the problem.
Check for loose or broken wires between
the thermostat
and the cooling
equipment.
Check Installer Setup, Function 3 (Fan Control), to make sure the fan
control is properly set to match the type of system (see page 8).
*
Check Installer Setup, Function
2 (Changeover Valve), to make sure it is
properly
configured
for your system (see page 8).
Check Installer Setup, Function
1 (System Type), to make sure it is set to
match the installed heating/cooling
equipment
(see page 8).
*
Check to make sure heating and cooling wires are not shorted
together.
12