Honeywell FocusPRO TH6220D Installation Manual page 18

Hide thumbs Also See for FocusPRO TH6220D:
Table of Contents

Advertisement

Installation
Guide
[f you
have
di[Yiculty
with
your
thermostat,
please
try the
suggestions
below.
Most
problems
can be corrected
quickly and easily:
Display is blank
*
Check circuit breaker and reset if necessary.
.
Make sure power switch
at heating & cooling system
is on.
Make sure furnace door is closed securely.
If thermostat
is battery
powered,
make sure fresh AA alkaline batteries
are correctly
installed (see page 10).
Temperature
se_ings
do not
change
Make sure heating and cooling
temperatures
are set to acceptable
ranges:
Heat: 40 ° to 90°F (4.5 ° to 32°C).
.
Cool: 50 ° to 99°F (10 ° to 37°C).
Check temperature
range stop settings (Function
27 & 28 on page 12).
Heating system
does not respond
("Heat On"
appears on
screen)
Cooling system
does not respond
("Cool On"
appears on
SCl%=en)
o
Check for 24 Vac at the equipment
on the secondary
side of the trans-
former between
power and common,
if voltage
is not present, check the
heating equipment
to find the cause of the problem.
*
Check for 24 Vac between the heat terminal (W) and the transformer
common,
if 24 Vac is present, the thermostat
is functional.
Check the
heating equipment
to find the cause of the problem.
o
Check for loose or broken wires between
the thermostat
and the heating
equipment.
Check for 24 Vac at the equipment
on the secondary
side of the trans-
former between
power and common,
if voltage
is not present, check the
cooling equipment
to find the cause of the problem
Check for 24 Vac between the cooling terminal
(Y) and the transformer
common.
If 24 Vac is present, the thermostat
is functional.
Check the
cooling system to find the cause of the problem.
Check for loose or broken wires between
the thermostat
and the cooling
equipment.
Fen does not
_
Check installer Setup, Function 3 (Fan Control), to make sure the fan
turn on in a ear
control is properly set to match the type of system (see page 11).
for heat
Heat pump
issues cool air
in heat mode_
OF warm
air
in
cool mode
o
Check Installer Setup, Function
2 (Changeover Valve), to make sure it is
properly
configured
for your system (see page 11).
Heat/cool
both
on at same time_
or heat does
not turn
off
Check Installer Setup, Function
1 (System Type), to make sure it is set to
match the installed heating/cooling
equipment
(see page 11).
Check to make sure heating and cooling wires are not shorted
together.