Pole Mounting the Power Injector Using AIR-PWRINJ-60-PMK=

You can mount the power injector on poles of up to 8 inches (25.4 mm to 203.2 mm) in diameter, using
the optional pole mount kit, AIR-PWRINJ-60-PMK=.
The AIR-PWRINJ-60-PMK= pole mount kit consists of:
Though there are no ventilation openings on the power injector, you are recommended to keep some
Note
clearance around the front of the product.
To mount the power injector on a pole, use for guidance, and follow these steps:
Mount the metal bracket of the AIR-PWRINJ-60-PMK= at the required position on the pole.
Step 1
Fasten the bracket to the pole using the worm screw clamps and the M6*110 hexagon head screw, flat
Step 2
washers, lock washers, and hexagon nuts. See
Cisco Aironet Series Power Injectors AIR-PWRINJ-60RGD1= and AIR-PWRINJ-60RGD2= Installation Instructions
Metal bracket
2 x Worm screw clamps
3 x M5X16 countersunk head Screw
4 x M6*110 hexagon head screw
8 x M6 flat washer
4 x M6 lock washer
4 x M6 hexagon nut
Pole Mounting the Power Injector Using AIR-PWRINJ-60-PMK=