Electrical
Requirements
Continued
Fire Hazard
Do not use an extension
cord.
Doing so can result in death, fire, or
electrical
shock.
Electrical
Shock Hazard
Plug into a grounded
three prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not fuse neutral or grounding
circuit.
Do not use air conditioner
with front
panel removed.
Failure to follow these instructions
can
result in death, electrical
shock, or
serious
injury.
Sprang
groundlng
Plug
115 volt models with amperes
-
up through 7.5
Receptacle
wiring
Receptacle wiring should be a minimum of
14 gauge. Use copper wire only. It is the
responsibility
of the consumer to provide
proper and adequate receptacle wiring,
installed by a qualified electrician. Observe
National Electrical Code and all local governing
codes and ordinances.
Electrical
requirements
A 115 volt (103.5 min., 126.5 max.), 60 Hz,
AC only, 15 ampere fused electrical supply is
required (time delay fuse or time delay circuit
breaker required). It is required
that a separate
circuit, serving only this air conditioner,
be
provided.
Electrical
connection
Electrical ground is required on this air conditioner.
Recommended
grounding
method
For your personal safety, this air conditioner
must
be grounded. This air conditioner is equipped
with a power supply cord having a 3-prong
grounding plug. To minimize possible shock
hazard, the cord must be plugged into a mating
3prong grounding-type
wall receptacle,
grounded in accordance
with the National
Electrical Code (ANSVNFPA 70 - latest edition)
and local codes and ordinances.
If a mating wall
receptacle is not available, it is the responsibility
of the customer to have a properly grounded
3-prong wall receptacle installed by a qualified
electrician.
4

Advertisement

Table of Contents
loading