6.4.23 AT+PWR Transmitting Power

Inquire
AT+ PWR?
Set
AT+ PWR =[para]
parameter
Description
Take effect immediately and save after power failure

6.4.24 AT+SLEEP Enter Sleep Command Immediately

Set
parameter
Description

6.4.25 AT+LOGMSG Operation Status Output

Inquire
Copyright ©2012–2019,成都亿佰特电子科技有限公司
Command
para(ASCII)
0
1
2
3
4
5
6
7
8
Command
AT+SLEEP
Command
AT+LOGMSG?
+OK=[para]
+OK:success
+ERR=[NUM]:error
0 dBm (default)
No
Effective immediately.
+OK=[para]
Response
val
4 dBm
3 dBm
-4 dBm
-8 dBm
-12 dBm
-16 dBm
-20 dBm
-40 dBm
Response
+OK
Response