DUSTLESS LOADING/SELF-CONTAINED DUSTLESS LOADING SPOUTS
GENERAL INSTALLATION
Burn-in should take place with the damper closed; this will ensure minimum amp draw and
reduce the risk of damaged equipment. If for any reason it is required that the damper be
opened, DO NOT open the damper more than 25% of the way from the fully closed position.
Fully opening the damper will cause overload and may damage the system.
Once burn in is complete, the damper may be adjusted as necessary to obtain the desired
volume flow rate by measuring the static pressure at the outlet and referencing that
measurement to the fan curve provided in the manufacturer's component data. Use care when
adjusting the volume flow rate to ensure that the maximum flow rate for the filters and the
maximum load on the exhaust fan motor is not exceeded.