R685
V620
C626
R683
C625
C627
C630
C628
R600
C629
R627
R628
Measure the resistances of R600 (~33 ohms), R627 (~0 ohms), R628 (~33 ohms)
and R683 (~0 ohms, all of class A, fig. 7.2).
If all of the measurements are correct, replace D600 (class B, fig. 7.2).
If the fault isn't fixed, send the phone to the next level.
4/00021-2/FEA 209 544/3.D
SH888, S868, Standare Electrical Repair
D600
65
Fig. 7.2
32
(66)