  • Page 1 VXR AUDIO STAND The Foundation of Great System Performance...
  • Page 2 Harmonic Resolution Systems, Inc. will enable your audio/video source and amplification components to achieve peak performance. The VXR Audio Stand, which includes the HRS Isolation Base as the primary shelf system, is a perfect match for the HRS Damping Plates, Nimbus, and Vortex products.
  • Page 3: Safety Instructions

    Safety Instructions IMPORTANT WARNINGS! Do not place any tall objects on the top shelf of the VXR Audio Stand. A tall object is any object with a height that is greater than the length of the isolation base. A tall object is also any object that has a height greater than its own width or length.
  • Page 4: Setup Instructions

    Always make sure you have the proper number of people to move the frame system safely and easily. The VXR Audio Stand consists of a frame structure and the isolation bases that support each component. The total number of boxes depends on the capacity of the system.
  • Page 5 Shipping or moving the vertical leg subassemblies by any means other than how it was originally packaged at HRS may result in permanent damage to the unit. Installation of VXR Adjustable Foot System - Unwrap two of the four feet supplied with the unit.
  • Page 6 Attaching the VXR Horizontal Crossmember Subassemblies - You are now ready to attach the horizontal crossmember subassembly to the vertical leg subassemblies. There are two braces that hold the two legs together to form the primary VXR Frame Structure. Take two of the VXR vertical leg subassemblies and lay them down on your soft work surface so that the outside edges are 19 inches apart for a VXR-1921 or 17 inches apart for a VXR-1719 (see Photo 5).
  • Page 7 (see Photos 7 and 8). Make sure the assembly is placed so that the HRS logo will be oriented correctly when the frame system is standing upright (see Photo 9), with the pocket for isolation base feet facing up away from the floor.
  • Page 8 Orient the HRS logo so that when the stand is sitting on its feet the HRS logo will be in the proper orientation. Make sure that all eight screws are fully installed connecting the horizontal crossmember subassembly to the legs, but 1/4 away from fully tightened before moving to the next assembly process.
  • Page 9 Install feet, nuts, and washers on the vertical leg subassemblies in the same way you did the first set. Unwrap two of the four feet supplied with the unit. Remove the nut and washer from each foot (see Photo 12). Photo 12 Hand-tighten the nut all the way down on each individual foot.
  • Page 10 Second VXR Vertical Leg Subassembly Installation - If you are assembling a VXR frame system that is more than one column wide, use all the double-sided vertical leg subassemblies (with bolt plates on two sides) before installing the second set of one-sided subassemblies. Carefully lower one leg onto the open side of the mount assemblies you already installed (see Photo 16).
  • Page 11 Repeat “VXR Vertical Leg Subassembly Installation” section to install the fourth vertical leg subassembly (see Photo 18). Photo 18 Torque all of the 1/4”-20x3/4" screws to rigidly secure all locations in the horizontal crossmember subassemblies to the vertical leg subassemblies (see Photo 19).
  • Page 12 You can now stand the frame up on its four feet. Clear any objects out of the way first to prevent damage to them or the stand. Then, at least two people should lift the top of the stand together to tip it onto its feet (see Photo 21). If your stand is only one column wide, skip the following instructions for doublewide systems and refer to the steps for final assembly.
  • Page 13 Have another person hold a horizontal crossmember subassembly in the desired place at the bottom of the stand and fasten it to the bolt plates using a 5/32” T- wrench and eight 1/4”-20x3/4” screws (see Photo 23). Attach the rest of the horizontal crossmember assemblies in the same way (see Photo 24).
  • Page 14 Place the supplied washer on top of the nut and then screw each of the feet into the threaded inserts on the bottom of the first vertical leg subassembly (see Photos 27 & 28). The feet should be threaded into the insert until the washer is held in contact with the bottom of the leg.
  • Page 15 Final Assembly of VXR Audio Stand - You are now ready to stabilize and level the frame. Move the frame to its exact final location for use in your system. Once the frame is in the final location, check to see if the frame is level and stable. If it is not, level the stand by extending the feet using the provided 1-1/4”...
  • Page 16 Photo 33 Loading Components into VXR Frame - Carefully load each component into the VXR Audio Stand. Be careful not to hit the front edge of the isolation base because you may scratch the aluminum frame. Once all the components are loaded, you should check to see that none of the isolation bases are overloaded.
  • Page 17 Remove the bottoms of the braces and set them aside as you did with the tops (see Photo 35). Keep the spacer pieces with the HRS logo and dampers attached to the bottom horizontal brace. Photo 36 shows all the...
  • Page 18 Photo 35 Photo 36 With the horizontal braces removed, you are now able to remove the eight fasteners securing the isolation base mounts to the vertical leg assemblies (see Photo 37). Have someone support the mounts as you do this so they do not fall onto lower parts of the frame system.
  • Page 19 1/4”-20x7/8” screws on the underside of each brace (see Photo 38). Make sure to orient the horizontal braces so the HRS logos are facing out. Refasten the brace tops at the center two holes first using two 1/4”-20x7/8” screws (see Photo 39).
  • Page 20 VXR Modular Leg Assembly/Extension - All the necessary equipment to disassemble and reassemble the modular vertical leg assemblies is included with your HRS VXR Audio Stand. Refer to these instructions if you need to disassemble your frame system for any reason, including altering the height by adding or removing leg sections.
  • Page 21 Always remove all components and isolation bases from the frame system before adjusting or removing any part of the VXR. Once the frame system and the area around it are free of any objects that may damage or be damaged by the VXR, prepare a work area the same as during initial assembly.
  • Page 22 Photo 48 Now use the 5/32” T-wrench and ratchet wrench to remove the 1/4”-20x3/4” screws holding each horizontal crossmember assembly to the final two vertical leg assemblies. Support each horizontal crossmember assembly as you remove its screws so it does not tip over. As you detach each horizontal crossmember assembly carefully lift it away from the vertical leg assemblies and set it aside on a clean, soft, surface where it will be out of the way until you begin reassembling the stand.
  • Page 23 Photo 50 With the first modular bolt plate section removed, the other(s) will be easy to lift out. Use the 1/8” T-wrench to remove the #10-24x3/4” fasteners from the two bolt plate section(s) adjacent to where you are adding or removing modular leg sections.
  • Page 24 With the leg sections in place and flush to each other, use the 1/8” T-wrench to fasten them together with the 1/4”-20x3/4” socket head screws (see Photo 53). Torque these screws until you can rotate the handle of the T-wrench 1/8 of a rotation without further turning the screw.
  • Page 25 Photo 54 If you are starting from one end of the vertical leg subassembly, first secure the top (or bottom) bolt plate section by using the provided 1/8” T-wrench to torque the #10-24x3/4” screws until you can rotate the handle of the T-wrench 1/8 of a full rotation without turning the screws any further.
  • Page 26 When all the vertical leg subassemblies are complete, refer to the “Attaching the VXR Horizontal Crossmember Subassemblies” section of this manual and follow the instructions to finish reassembling your HRS VXR Audio Stand. VXR Cable Organizer Accessory - The cable organizer system is available for the VXR as an accessory.
  • Page 27: Care And Maintenance

    Clean the metallic parts of the HRS Isolation Base and VXR Audio Stand using a lint-free soft (non-abrasive) cloth. Use a damp cloth with a mild soap or Pledge Surface Cleaner if required.
  • Page 28: Limited Warranty

    Limited Warranty Harmonic Resolution Systems warrants the product designated herein to be free of manufacturing defects in material and workmanship subject to the conditions herein set forth, for a period of 90 days from the date of purchase by the original purchaser.
  • Page 29 During the warranty period, Harmonic Resolution Systems will repair or replace any defective components free of charge. A Return Authorization Number (RA Number) obtained directly from Harmonic Resolution Systems is required before any product is returned to Harmonic Resolution Systems for any reason. This number must be visible on the exterior of the shipping container(s) for Harmonic Resolution Systems to accept the return.
  • Page 30 (MADE IN USA) All Harmonic Resolution Systems Inc. products are 100% Made In The United States of America by skilled craftsmen using only the finest materials and our personal dedication to the highest workmanship standards. ARMONIC ESOLUTION YSTEMS 2495 Main Street, Suite 227 Buffalo, NY 14214 Telephone: 716-873-1437 Web: www.AVisolation.com...