Single phase solid state relays

Advertisement

Quick Links

Main applications
• Packaging Machinery
• Thermoforming
• Plastic extrusion lines
• Industrial ovens and
furnaces
• Control application with
high switching speed
PROFILE
Zero crossing relay with antiparallel
thyristor output is the most used solid
state relay in industrial applications.
In fact, it can be used for resistive,
inductive and capacity loads.
"Zero crossing" relay is energised when
voltage meets the zero point and
disenergised when current meets the
zero point, depending on the signal
control on the input circuit.
This relay has been designed to stand
high-value transitory applications .
When the relay has to stand high
currents for a long period, it is necessary
to grant a proper dissipation and an
adequate electrical connection between
relay terminals and the load.
Varistors, fuses, thermostats and fans
are available as fittings.
Use the relay with an opportune heatsink
(see section accessories).
GQ 15 / 25 / 50 / 90 A
SINGLE PHASE SOLID STATE RELAYS
TECHNICAL DATA
General features
Rated frequency: 45...65Hz
Activation time:
GQ...-D- ≤1/2 cicle GQ...-A- ≤1 cicle
Deactivation time:
GQ...-D- ≤1/2 cicle GQ...-A- ≤1 cicle
Power factor: ≥0,5
Protection level: IP20
• U imp = 4,8KV
• U i
= 660V
• Overload current profile = 10
• Conditional short circuit current = 5KA
with type 1 coordination and respective
fuse protections.
GQ15/25
fuse type aM6A
GQ50
fuse type aM16A
GQ90
fuse type aM20A
GQ...- 24-
Nominal voltage: 24...230 Vac
(max range 20...253Vac)
Non-repetitive voltage: ≥ 600 Vp
Zero switching voltage: ≤ 20V
GQ...- 48-
Nominal voltage: 48...480 Vac
(max range 40...528Vac)
Non-repetitive voltage: ≥ 1200 Vp
Zero switching voltage: ≤ 40 V
Main features
• Alternating current solid state relay
• Zero crossing switching
• Copper/semiconductor coupling
technology
• 15, 25, 50 and 90Arms nominal
current
• Non-repetitive voltage: up to
1600Vp
• Nominal Voltage: up to 600 Vac
• Control voltage : 3...32Vcc and
20...260Vac/Vcc with connector
• Isolation ((input-output)
4000Vrms
• Red LED drive active signal
• Internal MOV (option)
GQ...- 60-
Nominal voltage: 48...600 Vac
(max range 40...660Vac)
Non-repetitive voltage: ≥ 1200 Vp
Zero switching voltage: ≤ 40V
Control input A1 - A2
GQ...-D-
Control voltage: 3...32Vcc
Turn ON voltage: ≥ 2,7Vc.c
Turn OFF voltage: ≤ 1Vcc
Reverse voltage: < 36Vcc
Consumption: ≤ 13mA@32V
GQ...-A-
Control voltage: 20...260Vac/Vcc
Turn ON voltage: ≥ 15Vac/Vcc
Turn OFF voltage: ≤ 6Vac/Vcc
Consumption: ≤ 8mAac/cc@260Vac/Vcc
Series connection of control inputs:
max. no. GQ...-A in series = Vcontrol
-10% / 20
Output L1 - T1
GQ - 15 -
Nominal current :
AC51: 15Arms; AC53: 3Arms
Min load current: 0,1Arms

Advertisement

loading

Summary of Contents for gefran GQ 15 A Series

  • Page 1 GQ 15 / 25 / 50 / 90 A SINGLE PHASE SOLID STATE RELAYS Main features • Alternating current solid state relay • Zero crossing switching • Copper/semiconductor coupling technology • 15, 25, 50 and 90Arms nominal current • Non-repetitive voltage: up to Main applications 1600Vp •...
  • Page 2 Repetitive overcurrent t=1 s: ≤ 35Arms Repetitive overcurrent t=1 s: ≤ 150Arms GQ - 50 - ≤ 125°C Non-repetitive overcurrent t=20ms:200Ap Non-repetitive overcurrent t=20ms: 1500 Ap Junction Temperature: ≤ 0,65 K/W Current drop at nominal voltage and Current drop at nominal voltage and Rth junction/case: frequencies: ≤...
  • Page 3: Electrical Connections

    spread 1 gram of thermoconductive sili- Attention cone paste (we recommend DOW COR- NING 340) on the dissipative metal surfa- The contact surface of the heatsink ces of the module. module may have a maximum planarity The surfaces must be clean and the ther- error of 0.1 mm and maximum roughness moconductive paste must not contain of 0.02 mm.
  • Page 4 GQ90... 100A FUS-100 FWP100A22F 12500A 22X58 338478 HEATSINK/ THERMAL TESISTANCE SECTION CABLE Model Section Model GEFRAN HEATSINK THERMAL RESISTANCE (see accessories) GQ15... 2,5mm GQ15... R th ≥ 2,8 K/W DIS 25GD R th ≥ 0,83 K/W GQ25... GQ25... DIS 50G GQ50...
  • Page 5 (*) Available only in versions GQ-XX-60-X-1-X Internal MOV (overloading protection always present) CONTROL VOLTAGE 3...32Vc.c. 20...260Vac/Vcc Please, contact GEFRAN sales people for the codes availability. GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice...
  • Page 6 To clean external plastic parts, use a clean cloth wet with ethyl alcohol or water. Technical service : GEFRAN has a technical service department. Defects caused by use not conforming to the instructions are excluded from the warranty.

This manual is also suitable for: