Technical Specifications
Weight
Type
[kg]
NHG 500 (L)
NHG 600 R (L)**
NHG 900 (L)
NHG 3000 (L)
29,0
*)
In this case the unbalance must be reduced to 2,19 cmkg.
**) See table of eccentric adjustments on page 11.
Note:
In order to protect the vibrators against too high speeds, a flow control
valve should be used to limit the oil flow to the permitted quantity (see
required oil).
As a control measure check the frequency with a sirometer.
Speed
Unbalance
[cmkg]
[rpm]
6,4
2,06
6.000
8,2
3,00
6.000
7,7
6,64
4.000
29,18
3.500
Long term operation
AT/h > 60%
Centrifugal
Flow
force
[N]
[l/min]
4.070
12
5.922
12
5.870
8
19.600
20
4
Short term operation
AT/h < 60%
Centrifugal
Speed
force
[rpm]
[N]
7.000
5.550
7.000
5.723*
5.000
9.100
4.000
25.600
Flow
[l/min]
14
14
10
22