Lubricating Intervals And Amount Of Lubricant For Atex Eth- Electro Cylinder; Relubrication Via Central Lubrication Port (Standard) - Parker ETH Series Operating / Mounting Instructions

Electro cylinder with atex, high force electro thrust cylinder
Hide thumbs Also See for ETH Series:
Table of Contents

Advertisement

Parker EME
3.2
Lubricating intervals and amount of lubricant for ATEX
ETH- Electro Cylinder
Lubricant
3.2.1.

Relubrication via central lubrication port (standard)

Lubricating intervals and amount of lubricant for ATEX ETH- Electro Cylinder

Spindle
Interval
ETH032
M05
80 km
M10
160 km
ETH050
M05
80 km
M10
160 km
ETH080
M05
80 km
M10
160 km
ETH100
M10
80 km
M20
160 km
ETH125
M10
60 km
M20
120 km
Do only use "Klüber NBU15" lubricating grease for standard
cylinders!
For applications in food related areas, "Klübersynth UH1 64-62" grease is used (customized version).
Grease gun
To relubricate the ball screw drive, use a grease gun suitable for the grease nipple.
We recommend a one-hand lubrication press with nozzle attachment type D1a4
(DIN3405). Both are optionally available:
nozzle attachment type D1a4 (DIN3405) - part No.: 180-006043
One-hand lubrication press with nozzle attachment type D1a4 (DIN3405) - part
No.: 180-006072
½ ∙ L
P
L
P
Figure 35: Relubrication via central lubrication port (standard)
1:
Central lubrication (standard)
2:
Central lubrication (Option)
Make sure that all external stops are removed.
Repeat the following process three times:
Retreat Electro Cylinder completely so that it touches the rear stop.
Move the cylinder by 0.5 mm into the internal buffer.
Ensure by means of control/controller that the internal buffer is not passed by
more than 0.5 mm!
This is the lubricating position.
Place the pipe orthogonally onto the lubricating nipple and press.
Use 1/3 of the defined amount of lubricant.
The amount of lubricant applied can be defined by the number of pump strokes.
Pump the stated amount of grease onto a balance, while counting the pump strokes.
For optimum distribution of the lubricant, a lubrication run must be performed
after each lubrication procedure. To do this, move the screw nut once over the
entire working stroke. For short-stroke applications (motion cycle < 2.5 spindle
rotation) see lubrication run lengths for short-stroke applications in the ETH
catalogue.
192-550003N10 ETH ATEX December 2019
Amount of lubricant
1.3 cm
3
1.6 cm
3
1.6 cm
3
1.9 cm
3
3.1 cm
3
4.4 cm
3
14 cm
3
17 cm
3
20 cm
3
48 cm
3
2
1
Ø10
½ ∙ L
P
45

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ETH Series and is the answer not in the manual?

This manual is also suitable for:

Eth032Eth050Eth080Eth100Eth125

Table of Contents