Parker EME
2.3.2.
Motor / gearbox mounting with parallel motor configuration
11
7
8
4
1
3
Figure 20: Parallel housing
Tightening torques for motor/gearbox assembly *
ETH
Coupling size/model
GS12 (outer diameter: 25 mm)
032
GS14 (Outer diameter: 30 mm)
050
GS19 (Outer diameter: 40 mm)
080
EK6-300, screws ISO4762 M6
100
EK6-450, screws ISO4762 M8
125
Table 1: Tightening torques for motor/gearbox assembly
* All clamping screws of the coupling halves must be secured (medium strength) by
a screw lock.
Parallel mount ETH100: ................................................................................................. 39
With parallel motor configuration, increased running noises are possible due to
the belt until it has run in.
2.3.2.1
Parallel mounting ETH032 ... ETH080 standard
9
14
6
13
12
10
15
2
5
192-550003N10 ETH ATEX December 2019
7
9
3
2
4
Figure 21: Motor mounting option
Motor mounting option (not valid for mounting Parker
EX motors)
Motor/ gear assembly
Tightening torque
1.4 Nm
1.4 Nm
10.5 Nm
12 Nm
35 Nm
6
8
1
5
35
Need help?
Do you have a question about the ETH Series and is the answer not in the manual?