  • Page 1 Flexi 7 Flexi 9...
  • Page 2 INFORMATION ON SOLID FUEL HEATING APPLIANCES According to Regulation (EU) No. 1185/2015 Manufacturer Aico Model identifier(s) Flexi 7 Brand Ravelli Indirect heating functionality Direct heat output 7,1 kW Indirect heat output -- kW Other η Preferred fuel Space heating emissions at...
  • Page 3 INFORMATION ON SOLID FUEL HEATING APPLIANCES According to Regulation (EU) No. 1185/2015 Manufacturer Aico Decò, Glass, Steel Model identifier(s) Flexi 9 Decò Brand Ravelli Indirect heating functionality Direct heat output 8,3 kW Indirect heat output -- kW Other η Preferred fuel...
  • Page 5: Preface

    Incorrect installation, maintenance and improper use of the product relieve the Manufacturer of all liability deriving from use of the stove. For further information and requirements contact your Ravelli-authorised Technical Assistance Centre. All rights reserved. No part of this instructions manual can be reproduced or transmitted through any electronic or mechanical means, in- cluding photocopies, recordings or any other storage system, for other purposes that are not exclusively use by the buyer’s staff, without...
  • Page 6: Table Of Contents

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.6 INDEX Preface..................................5 IDENTIFICATION .........................8 Stove identification ..............................8 Manufacturer identification ............................8 Reference standards ..............................8 Remote control: Synthetic Declaration of Conformity (DoC) ................8 Label ................................... 9 WARRANTY ..........................10...
  • Page 7 Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.7 CONTROLS AND USE .........................32 Control panel description ............................32 Radio touch remote control initialization ......................32 Description of the radio touch remote control ..................... 33 Description of the display ............................33 Time and date setting .............................
  • Page 8: Identification

    Remote control: Synthetic Declaration of Conformity (DoC) The manufacturer Aico S.p.A. declares that the Remote Control, with the Ravelli brand and model PNET00003 (Palm Touch) is in conformity with the relevant Union harmonisation legislation: 2014/53/EU (RED), and that the following harmonised standards and/ or technical specifications have been applied: ETSI EN 301 489-3, ETSI EN 301 489-1, EN 60950-1 A11+A1+A12+AC+A2, EN 62479.
  • Page 9: Label

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.9 Label Model: FLEXI 7 Model: Flexi 9 Déco APPARECCHIO PER IL RISCALDAMENTO DOMESTICO ALIMENTATO A PELLET DI LEGNO APPARECCHIO PER IL RISCALDAMENTO DOMESTICO ALIMENTATO A PELLET DI LEGNO...
  • Page 10: Warranty

    Use and maintenance manual Flexi 7 - Flexi 9 Pag.10 WARRANTY Certificate of warranty Ravelli thanks you for the trust granted with the purchase of one of its products and invites the purchaser to: • read the installation, use and maintenance instructions for the product; •...
  • Page 11: General Information

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.11 GENERAL INFORMATION Supply and safe-keeping The manual is supplied in printed format. Keep this manual safe, with the appliance, so that the user can consult it easily. The manual is an integral part, for safety reasons, therefore: •...
  • Page 12: Residual Risks

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.12 ⚠ Do not use any fuel other than fire pellet. It is strictly forbidden to use liquid fuels. ⚠ It is prohibited to use the appliance with the door or ash drawer open or the glass broken.
  • Page 13: Description Of The Appliance

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.13 Residual Description procedure-related information risk When the appliance is running, it may reach high Risk of temperatures to the touch, especially on its external burns surfaces. Take care to avoid burns and use the specific tools if necessary.
  • Page 14: Obligations And Forbidden Actions

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.14 Obligations and forbidden actions Obligations The user must: • read this instructions manual before performing any operation on the appliance; • the appliance must not be used by children under the age of 8 or...
  • Page 15: Characteristics Of The Fuel

    A2 and B. Maintain fuels and other flammables at a suitable distance. Ravelli recommends using wood pellet classified A1 and A2 according to the EN ISO 17225-2:2014 standard, or certified DIN PLUS (more restrictive than the A1 class) or ONORM M 7135. Pellet may be light or dark coloured, it is normally bagged into bags that show the name of the producer, the main characteristics and classification according to standards.
  • Page 16: Technical Characteristics

    The data shown here is provided as a guideline and is not binding, and may change based on what type and quality of wood is used. Ravelli reserves the right to make any changes in order to improve product performance.
  • Page 17: Minimum Clearances From Combustible Materials

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.17 Minimum clearances from combustible materials Units of Flexi 7 Flexi 9 measurement R Right side L Left side B Rear A Front 1000 1000 Measurements Unit of Flexi 7 Flexi 9 Déco...
  • Page 18: Technical Diagram Flexi 9

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.18 Technical diagram Flexi 9 50 AIR INLET 80 CANALIZATION 72,5 80 SMOKE OUTLET...
  • Page 19: Main Parts

    The heat generated by pellet combustion is diffused in the installation room by radiation and natural convection. It is possible to choose whether to activate the front fan or keep the stove in operation by natural convection. In addition, in the Flexi 9 versions it is possible to activate the ducting to heat another room, subject to activation by the installer.
  • Page 20: Recharge The Fuel

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.20 ⚠ Recharge the fuel ⚠ Use only wood pellets, the characteristics shown in this manual. During pellet loading prevent the pellet bag from coming into contact with hot surfaces.
  • Page 21: Safety Devices

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.21 Safety devices The stove has been designed and equipped with safety systems to minimize user risks. It is equipped with the safety devices listed in the following table, which also intervene in case of failure of the electronic board.
  • Page 22: The Majolica Cladding (If Applicable)

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.22 The Majolica cladding (if applicable) The Majolica cladding is artisan-crafted and hand-finished. For this reason there may be minor imperfections on the surface such as slight discoloration and hair cracks, which are ⚠...
  • Page 23: Shipping And Installation

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.23 SHIPPING AND INSTALLATION Safety warnings for transportation and installation �� The appliance must be installed by a qualified technician, who must issue a declaration of conformity of the system to the purchaser, taking full responsibility for appliance installation and correct operation.
  • Page 24: Set-Ups For The Smoke Evacuation System

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.24 ⚠ Use suitable equipment to remove the boards or wooden parts of packing. �� The end user is responsible for disposing of the packaging in accordance with the laws in force in the country of installation.
  • Page 25: Installation

    �� Ravelli shall not be held liable if these precautions are not followed. Requirements for the installation premises The appliance installation room must be sufficiently ventilated. To fulfil this requisite it is necessary to equip the room with an air intake connected to the outdoors.
  • Page 26 Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.26 Installation example This type of installation (See Fig.1) requires an insulated chimney pot, even if the entire conduit is installed inside the building. Besides, the structure must be inserted into a properly ventilated skylight shaft.
  • Page 27 Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.27 This type of installation (See Fig.4) requires an insulated chimney pot, even if the entire smoke conduit is installed outside the Protection from rain building. In the lower part of the chimney there is a "T" type fitting installed with inspection cap.
  • Page 28: Connections

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.28 CONNECTIONS �� The connections must be set up by a technician that is qualified and/or authorised by the Manufacturer. �� By the installer the type of cable, with relative section, to be installed in case of replacement is: H05RR-F sez.3G0,75 Connection with external air intake The stove has been designed for hermetic installations.
  • Page 29: Ducting

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.29 ⚠ Ducting Comply with the standards and laws in force in the region where the product is installed. �� This function must be activated by a qualified technician.
  • Page 30: Electric Scheme Flexi 7

    Rev.0 01/03/2023 G2- Conta colpi pulitore G1 -Extractor revolution extracteur G2 - Hubzähler automatischer G2 - Cuenta golpes limpiador au Use and maintenance manual Flexi 7 - Flexi 9 tomático automatico reading encoder G2 – Compte coups nettoyeur Reiniger Pag.30 G3- Palmare “Radio“...
  • Page 31: Electric Scheme Flexi 9

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.31 Electric scheme Flexi 9 RETE 230VAC LEGEND Safety devices Probes T1 - Pressure switch S1 - Flue gas probe (TCJ) T2 - Resettable thermal breaker S2 - Flame probe (TCK)
  • Page 32: Controls And Use

    Radio touch remote control initialization The remote control, after a first short screen showing the Ravelli logo, will list the languages available in the menu. Select the desired language with the scroll buttons and confirm your selection with the confirmation button.
  • Page 33: Description Of The Radio Touch Remote Control

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.33 Description of the radio touch remote control The remote control looks like the following picture: The information below will familiarize you with the product and give you the best performance.
  • Page 34: Time And Date Setting

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.34 Vers. 01 of:07.04.14 User’s manual HANDHELD TOUCH RADIO Pag.21 �� The display is subdivided into three parts: After 5 minutes of inactivity, the remote control display dims to “SLEEP” mode while maintaining the radio connection to the stove.
  • Page 35: Procedures For Use

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.35 ⚠ PROCEDURES FOR USE If the chimney catches fire you must call the fire brigade immediately. ⚠ Checks prior to start-up You have read and perfectly understood the contents of this instructions manual.
  • Page 36: Failed Ignition

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.36 Failed ignition If the system does not detect the ignition of the flame within the preset time, operation will be blocked with the “No ignition” alarm. Before relighting the stove, check that there are pellets in the hopper, that the door and ash drawer compartment are closed, that there are no obstructions to the combustion air inlet system and above all that, in models without self-cleaning brazier, the brazier is empty, clean and correctly positioned.
  • Page 37 Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 To exit the page and return to Stand-by page, press the button repeatedly. Pag.37 Control: ventilation can be set from 0 to AUTO where 0 indicates that the same is disabled, setting from MIN to MAX enables selecting the heat distribution speed.
  • Page 38 Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.38 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.30 Stove status Stove State Below are given the steps for accessing the relative menu starting from “Home” mode.
  • Page 39: Setting

    ENABLE COMFORT COMFORT CLIMA ENABLE COMFORT Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 ENABLE COMFORT Pag.39 RESTART DELTA SHUTDOWN DELAY COMFORT CLIMA COMFORT CLIMA COMFORT CLIMA DELTA COMFORT CLIMA DELTA In the inactive phases (combined with the 3rd part of the display) indicates the state of the stove.
  • Page 40 CONTRAST. Rev.0 01/03/2023 “confirm” to “selection” to switch “confirm” SETTINGS access the Use and maintenance manual Flexi 7 - Flexi 9 to the function to access the function SETUP CONTRAST. Pag.40 Use the UP/DOWN keys to change the WINTER/ SETTINGS By pressing the following key you will confirm of data SUMMER season.
  • Page 41: Ventilation Menu

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.41 Ventilation menu The stoves with optional fan use the natural convection system which guarantees a considerable amount of heat in the room with the total absence of noise given by the room ventilation. However, there is the possibility, by accessing the menu below, to activate the optional ventilation according to the power requested by you.
  • Page 42 Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.42 The top of the display shows the front ventilation speed. The bottom of the display shows the ducting output, which can be modified with the “increase/decrease” keys. The value which can be set goes from 0 (ducting off) to 5. Set at A (auto) the output of the fans follows the output of the stove.
  • Page 43 Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.43 CUBATURE CUBATURE CUBATURE Press the Press the “confirm” key “increase/decrease” keys to confirm the new setting to modify the setting. To go back to the CANALIZED menu, press the “back” key once; to go back to the Home screen, press the “back” key several times.
  • Page 44: Stove Phase General Layout

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.44 Stove phase general layout PHASE DESCRIPTION The stove is in the switch off phase and the cooling phase has FINAL CLEANING not been completed yet. The heater pre-heating phase has started and the pellets start to IGNITION fall into the grate.
  • Page 45: Warning Pop -Up

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.45 The stove has detected an anomaly; refer to the troubleshooting ANOMALY (general) chapter. By pressing the confirmation key, the problem is described. AUTOMATIC CLEANING For models with automatic cleaning system it indicates the SYSTEM ACTIVE operating state of the same.
  • Page 46 Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.46 The flue is blocked. Check the flue is free and clean AL 08 DEPRESSION The vacuum meter is faulty. Check the mains voltage. FUME The fume exhaust system has a loss of...
  • Page 47 Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.47 Wifi kit WIFI MODULE MOTHERBOARD (STOVE) Wifi external power supply kit (if applicable) WIFI MODULE MOTHERBOARD (STOVE) BOARD WITH CONNECTORS FOR EXTERNAL POWER SUPPLY CONNECTION EXTERNAL POWER SUPPLY...
  • Page 48: Installation Quick Guide Ravelli Smart Wi - Fi

    COLLEGARE IL CAVO DEL MODULO WiFi ALL’INGRESSO Rev.0 01/03/2023 COLLEGARE IL CAVO DEL MODULO WiFi ALL’INGRESSO SERIALE DELLA SCHEDA ELETTRONICA DELL’APPARECCHIO Use and maintenance manual Flexi 7 - Flexi 9 SERIALE DELLA SCHEDA ELETTRONICA DELL’APPARECCHIO (ESEMPI A e B) Pag.48...
  • Page 49 CONNECTION TO THE WiFi NETWORK Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.49 Click in succession > Networks. The Select wifi network screen will appear. Click Scan for networks: Connection to the WiFi network select your WiFi network and enter the password if required. Close the Click in succession >...
  • Page 50: Account Registration

    Deactivate the WiFi connection on your device, open the App and Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 click Access to cloud. Select Register your account, enter the required Pag.50 information (the name must not contain spaces) and click Register.
  • Page 51 Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.51 STEP 2 enter the product serial number and give the module a name living room stove); STEP 2 enter the product serial number and give the module a name (e.g. living room stove);...
  • Page 52: Maintenance

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.52 MAINTENANCE ⚠ Safety warnings for maintenance Maintenance of the stove must be performed at least once a year and should be planned in advance with the Technical ⚠...
  • Page 53: Extraordinary Maintenance

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.53 Glass cleaning With a cold stove, clean the glass with a cloth and glass cleaner. Note: there are stove glass cleaning products available on the market. Combustion chamber cleaning...
  • Page 54 Use and maintenance manual Flexi 7 - Flexi 9 Pag.54 Deep combustion chamber cleaning �� This operation must be carried out by a Ravelli Assistance Centre. �� Schedule this type of cleaning with the Ravelli Assistance Centre. To clean the combustion chamber, proceed as described below: After cleaning the combustion chamber, it is advisable to proceed with the cleaning of the inspection hatches as indicated in the para- graph “Smoke duct cleaning”.
  • Page 55 Checking the seals �� This operation must be carried out by a Ravelli Service Centre. Plan this type of cleaning with the Ravelli Service Centre. When thoroughly cleaning the stove, the authorised technician must check that the gaskets of - port...
  • Page 56: Troubleshooting

    Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.56 TROUBLESHOOTING The appliance does not work • Closely follow the directions in the dedicated chapter of this manual; • make sure that the air intake duct is not obstructed;...
  • Page 57 Rev.0 01/03/2023 Use and maintenance manual Flexi 7 - Flexi 9 Pag.57 - Cables - Motors - Fans - Circulators - Displays ELECTRICAL AND - Sensors ELECTRONIC - Spark plugs COMPONENTS - Electronic boards - Batteries Dispose of separately at authorised centres, in accordance with WEEE 2012/19/EU and its national...
  • Page 58 ITA-Informazioni per la gestione di rifiuti di apparecchiature elettriche ed elettroniche contenenti pile e accumulatori Questo simbolo che appare sul prodotto, sulle pile, sugli accumulatori oppure sulla loro confezione o sulla loro documentazione, indica che il prodotto e le pile o gli accumulatori inclusi al termine del ciclo di vita utile non devono essere raccolti, recuperati o smaltiti assieme ai rifiuti domestici.
  • Page 59 ESP-Información para la gestión de residuos de aparatos eléctricos y electrónicos con pilas y acumuladores Este símbolo que aparece en el producto, en las pilas, los acumuladores o en su embalaje o su documentación indica que el producto y las pilas o acumuladores que contiene, al final de su vida útil, no deben recogerse, recuperarse o desecharse junto con los residuos domésticos.
  • Page 60 Aico S.p.A. Headquarter Via Consorzio Agrario, 3/D - 25032 Chiari (BS) - Italy Research and Development Centre Viale del commercio 12/a - 37135 Verona (VR) - Italy T. + 39 030 7402939 info@ravelligroup.it FB Ravellifuocointelligente IG ravellistufe www.ravelligroup.it Aico S.p.A. does not assume any responsibility for any errors in this booklet and considers itself free to make any variations to the features of its products without notice.