Intec PolyGard 2 SC2 User Manual page 14

Toxic (e-), combustible (p-) and infrared (i-co2) gases
Table of Contents

Advertisement

SC2
SC2-AT6 – UserManual
Specifications subject to change without notice. | Tox_D_1119, Ex_D_1119, CO2_D_0320 | USA 200413 | Page 14 of 17
SENSOR PERFORMANCE TABLE
COMBUSTIBLE GASES
% LEL
P3485-A
C
H
O
0-100
3
6
P3408-A
NH
0-100
3
P3496-A
vapors
0-100
P3460-A
C
H
0-100
4
10
P3472-A
C
H
0-100
5
10
P3427-A
C
H
O
0-100
4
8
2
P3425-A
C
H
OH
0-100
2
5
P3410-A
C
H
0-100
2
4
P3491-A
C
H
0-100
7
16
P3435-A
C
H
0-100
6
14
P3476-A
C
H
0-100
5
12
P3482-A
C
H
O
0-100
3
8
P3498-A
JP8
0-100
P3402-A
LPG
0-100
P3400-A
CH
0-100
4
P3450-A
CH
OH
0-100
3
P3458-A
C
H
O
0-100
4
8
P3475-A
C
H
0-100
5
12
P3480-A
C
H
0-100
3
8
P3484-A
C
H
O
0-100
3
8
P3490-A
C
H
0-100
7
8
P3440-A
H
0-100
2
Manufacturer-recommended calibration interval for normal environmental conditions
1
The sensitivity of Pellistor sensors can be influenced by substances containing silicon compounds and even poisoned/destroyed by them.
2
INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
Specifications subject to change without notice. | USA 200303 | Page 4 of 5
2
± %LEL
%
< % sig.
t90 <
(CH
)
(CH
)
(CH
)
sec.
4
4
4
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
1
0.2
1
15
%
< % LEL /
°F
% RH
(CH
)
mo. (CH
)
4
4
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
0.5
0.3
1
-4/122
5-95
> mo.
Air = 1
ft
mo.
36
2.00
Floor
6
36
0.60
Ceiling
6
36
-
-
6
36
2.11
Floor
6
36
-
Floor
6
36
3.04
Floor
6
36
1.59
Floor
6
36
0.98
Ceiling
6
36
3.46
Floor
6
36
2.98
Floor
6
36
2.48
Floor
6
36
2.08
Floor
6
36
-
-
6
36
-
-
6
36
0.55
Ceiling
6
36
1.11
Floor
6
36
1.15
Floor
6
36
2.49
Floor
6
36
1.55
Floor
6
36
2.08
Floor
6
36
3.18
Floor
6
36
0.07
Ceiling
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Polygard 2 at6

Table of Contents