Sheet 1 of 16 Marine Lift Mechanism 1 IR ISSUE: 007 Remote Control Instruction Sheet www.futureautomation.co.uk Your Pack Should Contain 1 ML - Marine Lift Mechanism Suitable for 26" to 50" screens 1 Standard ML Fixtures Pack 1 Fixtures Pack The contents...
Page 3
Sheet 2 of 16 Marine Lift Mechanism CONTROLS ISSUE: 007 Instruction Sheet www.futureautomation.co.uk Connect the supplied IR remote and check that the Stage 1 mechanism operates correctly before continuing Check the operation of the mechanism with the installation. Firstly, remove all the red OUT: Reveal Screen cable ties which keep the mechanism safe and...
Page 4
The surfaces of the flap should ideally be varnished or painted to help prevent it from warping. Consult ML TECHNICAL SHEET before fabricating any Take care when fixing the surfaces Aluminum flaps or base panels.
Page 5
Sheet 4 of 16 Marine Lift Mechanism ISSUE: 007 Instruction Sheet www.futureautomation.co.uk Stage 3 Fixing the lift in the cabinet Place the mechanism within the cabinet. Raise the beam to the top and carfully guide the base through the opening in the top. With the base properly located, use the 8 pointed screws supplied, 4 on each side, to pin the mechanism in place, fixing its...
Page 6
Sheet 5 of 16 Marine Lift Mechanism ISSUE: 007 Instruction Sheet www.futureautomation.co.uk Stage 4 Adjusting the base panel height By adjusting the white screw up or down, you can adjust the stop height of the lifting beam and also, the base panel. DETAIL C SCALE 1 : 1.5 FUTUREAUTOMATION...
Page 7
Sheet 6 of 16 Marine Lift Mechanism HOLE FOR ISSUE: 007 CABLES Instruction Sheet www.futureautomation.co.uk You will also have to Stage 5 cut a hole in the base panel to allow the cables Positioning the base panel to pass up through to the plasma screen.
Page 8
Sheet 7 of 16 Marine Lift Mechanism CABINET TOP - SIDE VIEW ISSUE: 007 Instruction Sheet www.futureautomation.co.uk Stage 6 Adjusting the flap-up position By adjusting the white screw, at each side of the lift, you can adjust the tilt of the flap. CABINET TOP - PLAN VIEW By loosening the M6 bolts on each side under the flap, you can adjust...
Page 9
Sheet 8 of 16 Marine Lift Mechanism ISSUE: 007 Instructrion Sheet www.futureautomation.co.uk Stage 7 Adjusting the flap-down position DETAIL E SCALE 1 : 3 By adjusting the bolts under each flap arm, it is possible to alter the angle the flap opens to. It is very important that when the flap is open, it rests in a vertical position, as shown above.
Page 10
Sheet 9 of 16 Marine Lift Mechanism ISSUE: 007 Instruction Sheet www.futureautomation.co.uk Stage 8 Checking the screen mount With a standard marine lift, the supplied mounting type will be either a Group A or C framework, or a VESA 200 mount. Check that the type supplied suits the screen that is going to be mounted to the mechanism VESA 200 Mount Group A or C Framework...
Page 11
Sheet 10 of 16 Marine Lift Mechanism CABLES ISSUE: 007 Instruction Sheet When the screen is in www.futureautomation.co.uk position, the cables can be connected and run down Stage 9 into the cabinet. Fixing the screen to the lift Pass the cables through the hole you cut in the base Before mounting any screen, press STOP on the IR for the cables.
Page 12
Sheet 11 of 16 Marine Lift Mechanism ISSUE: 007 Instruction Sheet www.futureautomation.co.uk Stage 8 Fix the IR sensor and run the mechanism The IR sensor can be located anywhere outside of the cabinet. FUTUREAUTOMATION...
Sheet 12 of 16 Marine Lift Mechanism ISSUE: 007 Instruction Sheet www.futureautomation.co.uk Process Chip Electrical Connections Remove this screw to release the lid DETAIL H SCALE 2 : 2.5 Connect the Infrared Connect the IEC Power Lead Here Sensor here It is VERY important that when all of the electrical connections are made, the connector blocks are connected in the...
Sheet 13 of 16 Marine Lift Mechanism ISSUE: 007 Instruction Sheet www.futureautomation.co.uk Contact Closure Use an RJ45 connector in the CC1 socket on the control box pins to operate via contact closure. DESCRIPTION ACTION 12V SUPPLY CURRENT LIMITED When 12V is attached, device will go OUT. 12V TRIGGER When 12V is removed, device will go IN.
Page 15
Sheet 14 of 16 Marine Lift Mechanism ISSUE: 007 Instruction Sheet www.futureautomation.co.uk RS232 Use an RJ11 connector in the socket marked RS232 on the control box to operate using RS232. DETAILS Baud rate: 9600 Stop bit: Parity: None Databits: PROTOCOL ASCI Command fa_in = Device IN fa_out = Device OUT...
Sheet 15 of 16 Marine Lift Mechanism ISSUE: 007 Instruction Sheet www.futureautomation.co.uk Gives an ouput of 240V(or 110V) to Operation Details control the Marine Lift motor. Outputs stay live for 60 seconds after the OUT or IN fuctions are selected. EMERGENCY STOP This connection will stop all functions of the mechanism.
Page 17
Instruction Sheet www.futureautomation.co.uk Supplied Fixings The fixings below are the standard fixings supplied with every ML product. There will be one other pack of fixings supplied, containing fixings that are specific to the particular screen being mounted on the ML product.
Need help?
Do you have a question about the ML and is the answer not in the manual?