Samoa Larius GHIBLI SE 9000 Operating Instructions Manual

For sanitation 30:1 inox

Advertisement

Quick Links

w w w . l a r i u s . c o m
GHIBLI
FOR SANITATION
30:1 INOX
SE 9000
English

Advertisement

Table of Contents
loading

Summary of Contents for Samoa Larius GHIBLI SE 9000

  • Page 1 w w w . l a r i u s . c o m GHIBLI FOR SANITATION 30:1 INOX SE 9000 English...
  • Page 2 This manual is to be considered as an English language translation of the original manual in Italian. The manufacturer shall bear no responsibility for any damages or inconveniences that may arise due to the incorrect translation of the instructions contained within the original manual in Italian. Due to a constant product improvement programme, the factory reserves the right to modify technical details mentioned in this manual without prior notice.
  • Page 3: Table Of Contents

    GHIBLI 30:1 for sanItatIon GHIBLI 30:1 Airless pneumatic pumps for sanitation WARNINGS ................................p. 2 USE ..................................p. 3 WORKING PRINCIPLE ............................p. 4 TECHNICAL DATA ..............................p. 4 DESCRIPTION OF THE EQUIPMENT ........................p. 6 TRANSPORT AND UNPACKING ..........................p. 8 CONDITIONS OF GUARANTEE ..........................
  • Page 4: Awarnings

    GHIBLI 30:1 for sanItatIon WARNINGS The table below provides the meaning of the symbols used in this manual in relation to using, earthing, operating, maintaining, and repairing of this equipment. • Read this operator’s manual carefully before using the equipment. •...
  • Page 5: Buse

    GHIBLI 30:1 for sanItatIon SANITIZING FLUID APPLICATIONS ON: SANITIZING PRODUCTS SPRAYING EQUIPMENT The spraying of liquids under high pressure allows you covering • Office buildings, public bodies large surfaces with sanitizing agents, thus reducing the presence • Industrial sheds, factories, logistics centers of bacteria, fungi and viruses.
  • Page 6: Cworking Principle

    GHIBLI 30:1 for sanItatIon WORKING PRINCIPLE GHIBLI 30:1 pumps for sanitation are pneumatic pumps for high This allows for the material to be aspirated and pushed towards pressure sanitation without the use of compressed air (AIRLESS). the outlet. The unit comes complete with a transportation trolley, a The stainless steel version is particularly suitable for use with high-pressure material filter, an air supply regulator for the pump, a water-based paints.
  • Page 7 GHIBLI 30:1 for sanItatIon GHIBLI 30:1 The pump can operate continuously when the flow is limited to the white area. Outside of this area, the speed must be intermittent. L/MIN. 3200 1000 2800 2400 Always observe these instructions carefully when evaluating the product compatibility and 2000 in case of disposal of some parts of the pump no 1600...
  • Page 8: Edescription Of The Equipment

    GHIBLI 30:1 for sanItatIon DESCRIPTION OF THE EQUIPMENT Pos. Description Pos. Description Compressed air inlet High pressure filter out product Manometer reading air pressure alim. pump Recirculating cock Feed air pressure regulator. pump Recirculation pipe fitting fixing Trolley transport equipment Fluid recirculation pipe Valve opening and closing air alim.
  • Page 9 GHIBLI 30:1 for sanItatIon www.larius.com REV. 01 - 04/2020 - Cod. 150112...
  • Page 10: Ftransport And Unpacking

    GHIBLI 30:1 for sanItatIon TRANSPORT AND LIMITED 90-DAY WARRANTY UNPACKING • The packed parts should be handled as indicated in the Each LARIUS sanitizing sprayer is supported by symbols and markings on the outside of the packing. a 90-day warranty for the replacement of only •...
  • Page 11: Isetting-Up

    GHIBLI 30:1 for sanItatIon CAUSE SERIOUS INJURIES. • IN CASE OF INJURIES CAUSED BY THE GUN CASTING, If the product to be used is toxic, avoid inhalation SEEK IMMEDIATE MEDICAL ADVICE SPECIFYING THE and contact by using protection gloves, goggles TYPE OF THE PRODUCT INJECTED.
  • Page 12 GHIBLI 30:1 for sanItatIon • Open the recirculating cock (I5). CONNECTION OF SUCTION AND RECIRCULATING PIPES • Connect the high pressure flexible hose (I4) (not supplied; see accessories) to the pump and to the spray gun, paying attention to tighten the fittings strongly (the use of two spanners is suggested).
  • Page 13: Jworking

    GHIBLI 30:1 for sanItatIon WORKING • Lift the tank’s suction tube (I3). • Lean the spray gun against the rim of the container (I6) and drain the residual oil pressing the trigger. Release the trigger • Use the tooling after performing all the SETTING UP as soon as the clean liquid comes out.
  • Page 14 GHIBLI 30:1 for sanItatIon • Immerse the suction tube (J4) in the container (J5) of the product and the recirculation tube (J6) in a bucket (J7). • Open the recirculating cock. • Allow the product to circulate for a few seconds. Then close the recirculating cock.
  • Page 15: Kcleaning At The End Of The Work

    GHIBLI 30:1 for sanItatIon CLEANING AT THE END OF To tighten the packing nut (L1) use wrench supplied (L2). The packing nut must be tightened so as to avoid THE WORK wastes of product, but not excessively to avoid the seizure of the pumping piston and the wear of seals.
  • Page 16: Mmanual Reset Of The Pneumatic Motor

    GHIBLI 30:1 for sanItatIon MANUAL RESET OF THE • Remove the screws (N4) and the washers (N5). • Carefully extract the motor cylinder (N6) fom the pump. PNEUMATIC MOTOR • The feed air pressure of the pump must never be higher than the maximum value indicated in the technical data.
  • Page 17: Odisassembly Of The Pumping Group

    GHIBLI 30:1 for sanItatIon DISASSEMBLY OF THE PUMPING GROUP • Follow the end of work cleaning procedure before disas- sembling the pumping unit. • Remove the suction tube, the recirculation tube, the high- pressure tube that connects to the spray gun and the com- pressed air supply line’s connection tube •...
  • Page 18 GHIBLI 30:1 for sanItatIon TROUBLESHOOTING Problem Cause Solution The pump does not start Feed air not sufficient; Check on the air supply line. Increase the diameter of the feed hose; Outlet product line clogged; - Open the recirculation tap to check whether the pump starts up.
  • Page 19 GHIBLI 30:1 for sanItatIon Problem Cause Solution The pump works, but the flow of Suction valve worn or partially Disassemble the suction valve. product is not sufficien clogged; Clean and/or replace, if possible, the parts worn; Outlet product line clogged; Clean.
  • Page 21: Spare Parts

    GHIBLI 30:1 for sanItatIon SPARE PARTS Complete pneumatic motor pump Ghibli for TROLLEY/ WALL 30:1 pag. 20 C o m p l e t e f i l t e r s p l i t galvanized 30:1 pag. 24 Complete pumping pump Ghibli split version and stainless steel 30:1...
  • Page 22 GHIBLI 30:1 for sanItatIon COMPLETE PNEUMATIC MOTOR PUMP GHIBLI 30:1 TROLLEY AND WALL PUMP VERSION WARNING: always indicate code and quantity for each part required. www.larius.com REV. 01 - 04/2020 - Cod. 150112...
  • Page 23 GHIBLI 30:1 for sanItatIon PUMP COMPLETE MOTOR VERSION 30:1 TRAVERSE SCREWS KIT - COD. 40401 Code Description Pos. Description 96550 Complete motor trolley version 96550/2 Complete motor wall version Washer Gasket Bush Pos. Code Description Q. ty Valve 96001 Plug trolley version Complete screw valve 91602 Plug base pump and wall version...
  • Page 24 GHIBLI 30:1 for sanItatIon COMPLETE PUMPING PUMP GHIBLI GALVANIZED AND STAINLESS STEEL VERSION 30:1 WARNING: always indicate code and quantity for each part required. www.larius.com REV. 01 - 04/2020 - Cod. 150112...
  • Page 25 GHIBLI 30:1 for sanItatIon STAINLESS STEEL 30:1 SPLIT VERSION Cod. 98340 Pos. Code Description Q. ty 98340 omplete pumping 96023 Spring 91001/1 Oil tank 96233 'Oil' label 3429 O-ring 98501 Gaskets ring nut 96075 Complete tank 98358 V female ring 96074 PTFE gasket 96071...
  • Page 26: Scomplete Filter Split Ghibli 30:1

    GHIBLI 30:1 for sanItatIon COMPLETE FILTER SPLIT GHIBLI PUMP 30:1 WARNING: always indicate code and quantity for each part required. www.larius.com REV. 01 - 04/2020 - Cod. 150112...
  • Page 27 GHIBLI 30:1 for sanItatIon STAINLESS STEEL 30:1 VERSION Pos. Code Description Q. ty Complete filter M16x1,5 98388 Complete filter 1/4'' 98388/1 10107 Warning label 98384 Filter tank 96002 Trolley and wall label 30:1 96131 Trolley and wall label 40:1 96202 Sieve spring 95221 Filter sieve 200M...
  • Page 28 GHIBLI 30:1 for sanItatIon AIR REGULATION - TROLLEY AIRLESS VERSION Ref. 96250 WARNING: always indicate code and quantity for each part required. Pos. Code Description Q. ty Pos. Code Description Q. ty 96250 Complete group 96259 Manometer 96261 Reduction 8029 Screw TCE UNI 5931 M6x22 96214 Elbow...
  • Page 29: Uproduct Recirculation System

    GHIBLI 30:1 for sanItatIon PRODUCT RECIRCULATION SYSTEM WARNING: always indicate code and quantity for each part required. Pos. Codice Descrizione Q. tà 16613 Recirculating pipe www.larius.com REV. 01 - 04/2020 - Cod. 150112...
  • Page 30: Complete Trolley

    GHIBLI 30:1 for sanItatIon COMPLETE TROLLEY WARNING: always indicate code and quantity for each part required. Pos. Code Description Q. ty Pos. Code Description Q. ty 96320 Complete trolley 91047 Wheel washer 16271 Trolley handle 8029 Screw 16272 Trolley frame 95063 Washer 16954...
  • Page 31: Accessories

    GHIBLI 30:1 for sanItatIon ACCESSORIES SUCTION SYSTEM SE9040 3350/1 SE9041 Code SE9040 Suction tube for 30 lt drums Code 3350/1 Suction tube for 200 lt drums Code SE9041 Suction tube for 1000 lt drums FILTERS MESH Code 85014 FILTER 40 MESH Code 85012 FILTER 20 MESH Code 37215...
  • Page 32 GHIBLI 30:1 for sanItatIon AT250 AIRLESS GUN for sanitation High pressure spraying gun, max 250 bars. It includes the spraying nozzle and the 1/4” swivel fitting to connect to the tube. Code SE9050 Connection BSPP 1/4’’ Nozzle SFC 13-60 Code SE9050/1 Connection BSPP 1/4’’ Nozzle TSC 90-40 AT250 PISTON GUNSTOCk FILTERS Code 11039 Green (30M)
  • Page 33 GHIBLI 30:1 for sanItatIon SUPER FAST-CLEAN NOZZLE *Cod. Filter Ø inch Ø mm nozzle-angle recom. SFC07-20 0,007’’ 0,18 SFC07-40 200 M SFC09-20 0,009’’ 0,23 SFC09-40 SFC11-20 0,011’’ 0,28 SFC11-40 SFC13-20 SFC NOZZLE SUPER SFC13-40 0,013’’ 0,33 FAST-CLEAN SFC13-60 Yellow (see table) SFC15-20 100 M SFC15-40...
  • Page 34: Atex Certification

    GHIBLI 30:1 for sanItatIon ATEx CERIFICATION Safety instructions for using GHIBLI series pneumatic piston transfer pumps in high risk environments where potentially explosive gasses or vapours are present. DESCRIPTION These safety instructions refer to the installation, use and mainte- nance of LARIUS GHIBLI series pneumatic piston transfer pumps Larius GHIBLI series pneumatic piston pumps are in high risk environments where potentially explosive gasses or group II mechanical devices for use in areas where...
  • Page 35: Markings

    GHIBLI 30:1 for sanItatIon MARKINGS II 2 G c IIB T6 : -20°C ÷ + 60°C fluid: 60°C Tech. File: GHIBLI/ATx/08 max. II = Group II (surfaces) Category 2 (zone 1) Explosive atmosphere containing gasses, vapours or mists Design safety “c” T6 = Temperature class T6 - 20°C ÷...
  • Page 36 DICHIARAZIONE DI CONFORMITA’ CE DECLARATION OF CONFORMITY Il fabbricante / Company LARIUS srl Via Antonio Stoppani 21 - 23801 Calolziocorte (LC) ITALY Tel: +39 0341 621152 Fax: +39 0341 621243 E-mail: larius@larius.com Dichiara sotto la propria responsabilità che il prodotto: Declares under his owns resonsibility that the product: GHIBLI 30:1 è...
  • Page 37: Ab Pump For Sanitation

    GHIBLI 30:1 for sanItatIon PUMP FOR SANITATION Giotto Cod. SE9020 220V Cod. SE9021 110V Giotto with gravity hopper da 50 Lt. Cod. SE9022 220V Cod. SE9023 110V DALÌ Cod. SE9030 with hose reel 50 Lt. Cod. SE9031 with hose reel 30 Lt. Cod.
  • Page 38 LARIUS srl Via Antonio Stoppani 21 - 23801 Calolziocorte (LC) ITALY TEL. +39 0341 621152 - Fax +39 0341 621243 - larius@larius.com www.larius.com...