APPLICATION FIELD WIRING

WIRING DIAGRAM SHOWN BELOW FOR STANDARD RIELLO 530 SE/C PRIMARY CONTROL BOX.
INSTALLATION NOTE: ELECTRONIC AIR SHUTTER REQUIRES A CONSTANT 120V POWER SUPPLY TO
THE AUX TERMINAL, FAILURE TO PROVIDE THIS WILL RESULT IN NO BURNER OPERATION OR AIR SHUT-
TER WILL NOT CLOSE.
PLEASE NOTE: OPERATING LIMIT AND SAFETY LIMIT ARE TWO SEPARATE LIMITS.
Key to lay-out:
1
- Main disconnect fuse
2
- Manual service switch
3
- Safety limit device
4
- Operating limit device
5
- Earth ground connection burner chassis
6
- Burner control remote lock out alarm device - wired & supplied by others
AUX - Auxiliary bub base add-on connector (air shutter)
T - T - 24V thermostat connections - low voltage operated system
MIN. WIRE SIZE:
INSULATED 18 AWG SOLID OR 16 STRD.
PROPER EARTH GROUNDING MEANS REQUIRED
WARNING: DO NOT activate burner until proper oil line connections have been made, or failure of the pump
shaft seal may occur.
WARNING: DO NOT activate burner until all safety and operating controls have been wired in series with the
burner, as required by local code authorities and/or as specified by the appliance manufacturer.
3223
AIR SHUTTER
MOTOR
RATED 105° C
ALL WIRING SHOWN PROVIDED BY OTHER.