Step 1 – Install the Flow Devices
Follow the instructions that came with your flow devices to install them in the proper locations for
monitoring the flow from your water sources.
Create a diagram that shows your control points by number and the serial numbers of the associated
flow devices.
Step 2 – Search For and Assign the Flow Devices
The BaseStation 3200 supports up to 8 flow sensors or meters, which manage and monitor flow across a
site when associated with a control point.
In addition to finding flow biCoders, this search finds two-wire flow meters with integrated master
valves.
1. On the BaseStation 3200 controller, turn the dial to the Assign position.
2. Press the Next or Previous button to select Assign biCoders to Flow Meters, and then press the
Enter button.
3. Press the + or – button to select Search in the biCoders column.
4. Press the Enter button to search for flow meters. The display shows the serial numbers of the
devices found in the left column and the numbered ports or addresses available in the right column.
5. Press the + or – button to select the flow meter that you want to assign.
6. Press the Next or Previous button to move to the Flow Assignments column and select an available
number.
7. Press the Enter button to assign the selected flow meter to that number.
8. When you have finished making changes, turn the dial to the RUN position.
Step 3 – Search For and Assign the Master Valves
1. Turn the dial to the Assign position.
2. Press the Next or Previous button to select Assign biCoders to Master Valves, and then press the
Enter button.
3. Press the + or – button to select Search in the biCoders column.
4. Press the Enter button to search for flow meters. The display shows the serial numbers of the
devices found in the left column and the numbered ports or addresses available in the right column.
5. Press the + or – button to select the flow meter that you want to assign.
6. Press the Next or Previous button to move to the MV Assignments column and select an available
number.
7. Press the Enter button to assign the selected master valve to that number.
8. When you have finished making changes, turn the dial to the RUN position.
Baseline Support: 866-294-5847
BaseStation 3200 – Setting Up Water Source Priorities
2
www.baselinesystems.com