Before assembly Note Read these assembly instructions completely before working with the storage stove! They contain important information for your personal safety. 1.1. Floor load-bearing capacity: Before assembly, make sure that the load-bearing capacity of the substructure is sufficient to bear the weight of the stove. Strong oscillations of flexible substructures (timber floors) can lead to defects in the stove and make the installation of rotating stoves impossible.
1.3. Safe distances: CAUTION CAUTION Fire prevention laws stipulate minimum or safe distances for inflammable materials (wood panels, panelling, fabrics, etc.). These are given by the table below: Safe distance A Sides and rear panels require a minimum distance of 10 cm to inflammable materials Safe distance B The national and local rules and regulations...
DIN EN 13384-1:2008-08 and DIN EN 13384-2:2009-07. Tonwerk Lausen AG recommends and supplies the Lindab connecting system for the combustion air supply. The required elements must be specified when ordering.
1.7. Supply-air connection underneath / at the rear T-ART Commercially available flue pipe Ø150mm, wall thickness 2 mm, with Chimney connection sealed cleaning aperture if sealed with rope seal or necessary high-temperature silicone Fastening to TL elbow support with Lindab hose clamp TKS-R- 165.
1.8 Connection to a combination air/flue gas chimne Flue pipe d=150 Commercially available flue pipe Wall thickness 2 mm with sealed cleaning aperture Seal chimney connection with rope seal or high-temperature silicone! Flue gas chimney Supply air: Thermally isolated from the flue gas pipe Special connecting piece TL article 167001.000002...
Each appliance is assembled and checked for completeness and damage during the works acceptance. However, if you should find defects that are attributable to transport damage, contact Tonwerk Lausen AG immediately after delivery. WARNING Heavy components Components can be very heavy. Inappropriate handling leads to serious...
3. Assembly steps 3.1. Step 1: See turntable option for versions with a turntable! 3.2. Installing the stove housing Level the housing and align and measure for the chimney connection taking the upper sheet metal cover as the basis. Note The stove can no longer be moved once assembly is complete.
Page 10
Note The free cross-section of 125 mm may not be reduced. In particular when connecting to the exterior facade, care must be taken that the supply air pipes are adequately insulated in order to prevent the formation of condensation. IMPORTANT Important! In the case of long supply air pipes >...
3.4. Step 3: Installing the heat storage blocks 3. Remove the sheet metal screen 1. Position the stove housing 4. Unscrew the storage cover 2. Unscrew the start-up flap 6. Clean the surface of the bottom storage stone 5. Insert the bottom storage stone and push it right to the back.
Page 12
11. Insert the front storage plate and refit the 10. Slide the flue gas baffle start-up flap at the top plate in from above 12. Test the function of the start-up flap 13. Refit the storage cover and ensure that the seal is positioned correctly 14.
3.5. Step 4: Installation the stove cladding 1. Carefully mount the left side plate at the bottom of the housing with the centring pin (A) and turn it to the front 2. Turn the side plate to the front, aligning it with the pane of glass;...
Page 14
4. Unscrew the start-up flap control knob (A), mount the rear panel (B) and screw down at the top and bottom Screw the control knob back on 5. Place the cover stones back on top...
3.6. Step 6: Function test – door closure Note Before putting into operation, check that the locking lever of the closing mechanism moves beyond dead centre to the stop and locks the door properly. 3.7. Step 7: Function test – supply air mechanism Note Before connecting the supply air, check that the air flap closes by pressing the reset button (audible closing noise).
3.8. Step 8: Commissioning, instruction and lighting Light the stove and instruct the user on the basis of the operating manual. Draw the customer’s attention to the safety and application information. Note Inform the customer that a defective seal must be replaced immediately for safety reasons.
Page 17
A These holes are for fixing the turntable (delivery condition) B Latching bolts for latching in the desired position Assembly = screw in to the stop, then ½ turn back out, secure with lock nut Stop for 45°angle of rotation (Total angle of rotation = 90°...
Complete the warranty certificate in the presence of the customer and return it to us. Please contact our Customer Service Dept. on +41 (0) 61 935 17 10 if you should have any questions. Subject to change without notice: Bubendorf, February 2017 info@tonwerk-ag.com www.tonwerk-ag.com Tiba AG Hauptstrasse 147 CH-4416 Bubendorf...
Need help?
Do you have a question about the T-ART eco2 and is the answer not in the manual?
Questions and answers