Programming Instructions For Ekey Switch-Lock System - TAB-Austria Golden Island VC2 Operator's Manual

Table of Contents

Advertisement

Programming instructions for EKEY
Switch-lock system
Main key system:
Main Key: Exclusively programmed while in factory shipped state.
Is used to erase all other keys.
Programming Key: Exclusively programmed while in factory shipped state.
Is used to program the Service keys.
Service Key:
A Service key gives access to service- and booking functions at your machine.
Up to four service keys can be programmed and used.
ystem
Programming of Main key s
:
While in factory shipped state a LED flashes (2x per second) after power up!
Attention, if LED is not flashing, the main key system is already programmed!
Insert Main key until LED goes off for short time, then disconnect.
Insert Programming key until LED goes off for short time, then disconnect.
LED goes off permanently.
Programming is done by a successive short inserting of the keys (approximately 1 sec.).
Hint: Accepted keys are identified by LED going off short.
Programming:
(only in conjunction with main key)
Erase all keys l(programming- and service key:
Insert main key for approximately 20 seconds, LED goes off shortly.
Programming key:
Only possible while in factory shipped state or after erasing all keys.
Service key:
First select the output with one of the four DIP-SWITCH by moving it to the ON position.
Then insert the Programming key shortly - LED is flashing (10x per second), Disconnect
Programming key and insert the Service key you want to correlate with – the output activates
immediately – DIP-Switch to OFF – Programming finished.
For total you can program 1 Main key, 1 Programming key and 4 Service keys.