Motorized Rotary Actuator
6.2 Retrofitting of two additional travel switches (2EZ)
Disconnect actuator from power supply before starting work!
Danger
1. Remove the two allen screws [1] on the main switch board. Replace them with two
spacer bolts [3].
2. Clip the spacer [2] into the main switch board.
3. Clip the additional switch board [4] onto the spacer [2] and fix with the allen screws [1].
4. Adjust the cams according to the instructions in section 5.2
1
3
Fig. 6:
Retrofitting of two additional travel switches (2EZ)
W. Baelz & Sohn GmbH & Co. · Koepffstrasse 5 · 74076 Heilbronn · Germany · www.baelz.de
2
4
1
1
3
4
2
baelz 375-E42
1
3
Seite | Page
14 |
32