Parameters Description
P23
Photovoltaic mode integration
P24
Off-peak working mode
P25
Offset value on upper water temp probe
P26
Offset value on lower water temp probe
P27
Offset value on air-inlet temp probe
P28
Offset value on defrosting temp probe
P29
Antilegionella starting hour
Hysteresis on upper water probe for electrical
P30
heater working
Heat-pump working period in AUTO mode for
P31
heating rate calculation
Temperature threshold for electrical heater us-
P32
age in AUTO mode
P33
Electronic-expansion valve (EEV) control
Superheating calculation period for EEV auto-
P34
matic control mode
Superheating setpoint for EEV automatic con-
P35
trol mode
Desuperheating setpoint for EEV automatic
P36
control mode
P37
EEV step opening during defrosting mode (x10) 5÷50
Minimum EEV step opening with automatic
P38
control mode (x10)
P39
EEV control mode
Initial EEV step opening with automatic control
P40
mode / EEV step opening with manual control
mode (x10)
P41
AKP1 temperature threshold for EEV KP1 gain -10÷10°C
P42
AKP2 temperature threshold for EEV KP2 gain -10÷10°C
P43
AKP3 temperature threshold for EEV KP3 gain -10÷10°C
P44
EEV KP1 gain
P45
EEV KP2 gain
P46
EEV KP3 gain
Maximum allowed inlet temperature for heat-
P47
pump working
Minimum allowed inlet temperature for heat-
P48
pump working
Threshold on inlet temperature for evaporator
P49
EC or AC with double speed blower speed set-
ting
P50
Antifreeze lower water temperature setpoint
P51
Evaporator EC blower higher speed setpoint
P52
Evaporator EC blower lower speed setpoint
(1) = NOT USABLE FOR THIS EQUIPMENT
Range
0 = permanently deactivated
1 = activated
0 = permanently deactivated
1 = activated with ECO
2 = activated with AUTO
-25÷25°C
-25÷25°C
-25÷25°C
-25÷25°C
0÷23 hours
2÷20°C
10÷80 min
0÷20°C
0 = permanently deactivated
1 = activated
20÷90s
-8÷15°C
60÷110°C
3~45
0= automatic
1 = manual
5÷50
-10÷10
-10÷10
-10÷10
30÷50°C
-10÷10°C
10÷40°C
0÷15°C
60÷100%
10÷60%
cod. 3541T580 - Rev. 00 - 12/2019
Default
0
0
0°C
0°C
0°C
0°C
23 hours
7°C
30 min
4°C
1
30 s
5°C
88°C
15
9
0
25
-1°C
0°C
0°C
5
2
1
43°C
-5°C
25°C
12°C
90%
60%
Note
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable