Rainfresh CAFE 948 Installation & Operation Instructions

Rainfresh CAFE 948 Installation & Operation Instructions

Air injection iron filter

Advertisement

Thank you for purchasing one of our ENVIROGARD / Rainfresh Iron Filter Systems. We are committed to
ensuring that you are totally satisfied.
If you have any problems, don't go back to the store - please contact us ! Most issues can be resolved
over the phone.
System Specifications.................................................................................................... 1
How The CAFE System Works ....................................................................................... 2
Cautions Before Installation ................................................................................................. .. 2
How to check well pump flow rate .......................................................................................2
Installation .................................................................................................................... 3
a) Unpacking the unit ................................................................................................. ...... 3
b) Plumbing the Filter unit ............................................................................................. .. 4
c) Start-up and Programming ........................................................................................ .. 6
Other Features ............................................................................................................. 8
Troubleshooting ............................................................................................................ 8
Parts List .................................................................................................................................. 9
Warranty....................................................................................................................... 9

SYSTEM SPECIFICATIONS:

Rated Service
Model No.
Flow
US GPM (LPM)
CAFE 948
2.2 (8.3)
Water Temp - 4 - 38°C (39 - 100°F)
Water pH Range - 6.8 to 8.5*
Max Raw Water Turbidity - 5 NTU
Max Raw Water Iron - 15 PPM
Alkalinity > [2 x (Sulphates + Chlorides)]
*
Higher the pH, better the performance. If pH is lower than 6.8, call Rainfresh for information on ordering a pH Neutralizing Filter
RAINFRESH CAFE AIR INJECTION IRON FILTER
Installation & operation instructions
Help Line : 1-800-667-8072
Monday to Friday 8:30 AM to 5:00 PM EST
Website : www.rainfresh.ca

TABLE OF CONTENTS

Max Flow
Backwash
Rate
Flow Rate
US GPM
US GPM
(LPM)
(LPM)
5 (19)
5 (19)
Drain
Electrical
Inlet /
Connec
Require
Outlet
tion
ment
3/4"
1/2"
110V
MNPT
Hose
AC
Chlorine - Nil
Oil in Water - Nil
Polyphosphates - Nil
Hydrogen Sulphide - Nil
Pressure
Operating
Drop
Pressure
< 15
30 - 100
psig
psig
Shipping
Weight
(lbs)
82

Advertisement

Table of Contents
loading

Summary of Contents for Rainfresh CAFE 948

  • Page 1: Table Of Contents

    Max Raw Water Iron – 15 PPM Hydrogen Sulphide - Nil • • Alkalinity > [2 x (Sulphates + Chlorides)] • Higher the pH, better the performance. If pH is lower than 6.8, call Rainfresh for information on ordering a pH Neutralizing Filter...
  • Page 2: How The Cafe System Works

    You may need to either change the well pump or call Rainfresh for a custom size unit that will operate within your pump specifications.
  • Page 3: Installation

    (5/40) x 60 = 7.5 GPM. INSTALLATION Figure 1. Piping Schematic a) Unpacking the unit The Rainfresh CAFE filter system includes: 1) The main media tank with automatic electronic control valve 2) 110V AC power adapter for control valve 3) Air Injector 4) By-pass valve &...
  • Page 4: B) Plumbing The Filter Unit

    Plumb in the inlet and outlet of the CAFE filter. We recommend using Fig 4 Rainfresh CKS solder-less connector kit for easy installation. This can be Fig 5 ordered from the same retailer where you purchased the unit from, or call Rainfresh.
  • Page 5 o It is also recommended to install threaded unions on both ends of the air-injector to allow easy removal for inspection and service. Fig 7 Before proceeding further, make sure that the bypass valve is in the bypass position (fig 7) Close all open taps and turn on the switch for the well pump.
  • Page 6: C) Start-Up And Programming

    We recommend setting backwash every 3 days with a minimum 10 minute backwash and 5 minute rinse cycle. If you have questions about programming, please call Rainfresh at 1800-667-8072. When power is first supplied, the valve electronics may take up to two minutes to initialize. During this time the screen will show “INTIALIZING WAIT PLEASE”.
  • Page 7 The unit is factory set to backwash at 2:00 AM on the day of backwash. You can change to another time if desired. 3 Days Regeneration Days Leave at default setting. Before changing this value, contact Rainfresh Backwash Leave at default setting Rapid Rinse...
  • Page 8: Other Features

    Manual Backwash If screen is locked, press “ MENU” for 3 seconds to unlock. To start an immediate backwash, Press the SET/REGEN button for 3 seconds, an option for “Delayed” or “Immediate” backwash will • appear. Press the SET/REGEN button again and “Delayed” will begin flashing. •...
  • Page 9: Parts List

    This warranty applies only to water filter/systems purchased in Canada or the U.S.A. Envirogard Products Limited 6-446 Major Mackenzie Drive East, Richmond Hill, ON L4C 1J2, CANADA Toll Free: 1800 667 8072 Tel: (905) 884 9388 Fax: (905) 884 3532 E-Mail: info@rainfresh.ca Web: www.rainfresh.ca...

Table of Contents