Summary of Contents for Rainfresh CBF1

  • Page 1: Table Of Contents

    Installation & Operation Manual (Please save for future reference) Thank you for purchasing one of our ENVIROGARD / Rainfresh products. We are committed to ensuring that you are totally satisfied. If you have any problems, don’t go back to the store– please contact us ! Most issues can be resolved over the phone.
  • Page 2: System Specifications

    HOW YOUR CBF1 FILTER WORKS Your Rainfresh CBF1 Filter removes sediment, dirt, rust, sand & other particulate matter using a special grade of filter sand which traps the particulates down to 5 micron nominal. Once every 3-4 days, the unit backwashes to remove the trapped sediment and dump it to drain.
  • Page 3: Installation

    The automatic control valve requires a constant power supply - 120V/60 Hz AC. We recommend a GFI (ground fault interrupter) outlet within 5 feet of the CBF1 Filter. Extension cords are not recommended. If water pipes are used to ground electrical system, you will need to install a jumper wire across the filter unit.
  • Page 4: C) Installation Location

    You may choose not to treat the water spigots that go outside used for irrigation or sprinkler systems. You will have to plan the job so that you cut in to feed the CBF1 filter AFTER these spigots. Installing the CBF1 filter after the pressure tank on a well water system is the preferred location.
  • Page 5: D) Plumbing The Filter Unit

    For ease of installation, orient the inlet/outlet fittings in the direction of the inlet & outlet pipes by simply rotating them (Fig 5B) Plumb in the inlet and outlet of the CBF1 filter. Plumb in a ½” flexible plastic drain line running from the filter (elbow hose fitting) (Fig 6).
  • Page 6: E) Start-Up And Programming

    The valve has 2 levels of programming – Level 1 and Level 2. need to change any settings other than time and date. Please call Rainfresh before attempting to change any values as that can affect the performance of your unit.
  • Page 7: Level 1 Programming

    Level 1 PROGRAMMING STEP 1 : Set Current Time C U R R E N T T I M E C U R R E N T T I M E C U R R E N T T I M E C U R R E N T T I M E P R E S S M E N U K E Y P R E S S M E N U K E Y...
  • Page 8 STEP 2 : Set Current Date C U R R E N T D A T E C U R R E N T D A T E C U R R E N T D A T E C U R R E N T D A T E C U R R E N T D A T E C U R R E N T D A T E C U R R E N T D A T E...
  • Page 9: Level 2 Programming

    CAUTION: DO NOT CHANGE LEVEL 2 SETTINGS WITHOUT CONSULTING RAINFRESH TECHNICIAN (1-800-667 8072). Wrongly changing the settings can result in malfunction of the unit. When the Level 2 Master Programming Mode is entered, all available option setting displays may be viewed and set as needed.
  • Page 10: Manual Backwash

    MAINTENANCE The CBF1 filter does not require any routine maintenance except ensuring that it backwashes regularly. There are no filters or parts to be replaced. Typically, after a few years of service (5-7), you may notice that some sediment is present in filtered water.
  • Page 11: Troubleshooting

    See video at http://rainfresh.ca/how_to_videos.php K. My display screen is 1. Power cord may be unplugged 1. Re-connect power cord blank from either adapter or receptacle 2. Call Rainfresh to receive new circuit board 2. Defective circuit board with replacement instructions...
  • Page 12: Exploded Diagram & Parts List

    PARTS LIST Item No. Part No. Description Quantity 05056087 Screw - M5x12 (Hexagon) 05056088 Screw - M5x16 (Hexagon with washer) 05056047 End plug retainer 05030002 Piston rod 05056097 Piston pin 05056023 End plug 05056070 Quad ring 05056024 End plug washer 05056022 Piston retainer 05056181...
  • Page 13 05056140 Valve connector 05056065 O-ring φ 23.6x2.65 21319006 Screw adaptor 05056508 Screw M5x12 (Hexagon with washer) 05030004 End cover 05030013 O-ring φ 30x2.65 13000426 Screw-ST2. 9x13 (Large) 07060007 Valve bottom connector 26010103 O-ring φ 25x3.55 05056063 O-ring φ 78.74x5.33 05056086 Screw - M5x30 (Hexagon with washer) 05056029 Injector cover...
  • Page 14: Warranty

    Limited Warranty: This CBF1 System is warranted to the original instructions received from the Warrantor. This Consumer purchaser for a period of one (1) year, warranty does NOT cover, and is intended to from the date of purchase, against defects in exclude, any liability on the part of Envirogard for materials or workmanship.