Datexel DAT 4631 B Manual

Isolated doubler / converter

Advertisement

Quick Links

Via monte Nero, 40/B – 21049 TRADATE (VA) ITALY
Phone: +39 (0)331841070 Fax:+39 (0)331841950 -
FEATURES
- Configurable input for RTD and resistance
- Double output configurable in current or voltage
- Configurable by dip-switch or PC
- High accuracy
- On-field reconfigurable
- Galvanic isolation among the ways
- EMC compliant – CE mark
- Suitable for DIN rail mounting in compliance
with EN-50022 and EN-50035
GENERAL DESCRIPTION
The isolated doubler/converter DAT 4631 B is able to measure and linearise the standard RTDs and resistances with 2 or 3 wires cable compensation .
In function of programming, the measured values are converted in a current or voltage signal. The device guarantees high accuracy and performances
stability both versus time and temperature.
The programming is made by the dip-switch located in the window on the side of the enclosure. By means of dip-switches it is possible to select the input
type and range and the output type without recalibrate the device.
Moreover, by Personal Computer the user can program all of the device's parameters for his own necessity; the configuration by PC allows to program
the two outputs with two independent settings. For all the sensors it is possible to set the cable compensation with 2 or 3 wires.
Moreover it is available the option of alarm for signal interruption (burn-out) that allows to set the output value as high or low out of scale .
The 1500 Vac galvanic isolation on all ways (input, outputs and power supply) eliminates the effects of all ground loops eventually existing and allows the
use of the converter in heavy environmental conditions found in industrial applications.
The DAT 4631 B is in compliance with the Directive 2004/108/EC on the Electromagnetic Compatibility.
It is housed in a plastic enclosure of 12.5 mm thickness suitable for DIN rail mounting in compliance with EN-50022 and EN-50035 standards.
USER INSTRUCTIONS
The converter must be powered by a direct voltage applied to the terminals Q and R.
The analog channel measures the value from the sensor connected to the terminals the I, L and G and transmits the output measures on the terminals N
and M (OUT A) and the terminals P and O (OUT B).
The input and output connections must be made as shown in the section "Connections".
It is possible to configure the converter on field by dip-switch or Personal Computer as shown in the section " Programming ". The configuration by dip-
switches can be made also if the device is powered (note: after the configuration the device takes some seconds to provide the right output measure ).
INPUT
Input type
Min
RTD (
2, 3 wires)
Pt100
-200°C
Pt1000
-85°C
Ni100
-60°C
Ni1000
-60°C
0 Ω
RES.
(2, 3 wires)
0 Ω
Input Calibration
(1)
RTD
the higher of ±0.1% and ±0.2°C
the higher of ±0.1% and ±0.15 Ω
Low Res.
the higher of ±0.2% and ± 1 Ω
High Res.
Linearity
(1)
RTD
± 0.1 % f.s.
Sensor excitation current
RTD,Res
500 uA
Line resistance influence
(1)
0.05%/Ω (50 Ω max balanced)
RTD 3 wires
Thermal drift
(1)
Full scale
± 0.01% / °C
(1)referred to the input Span (difference between max. and min.)
e-mail:datexel@datexel.it
TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions)
OUTPUT (2 CHANNELS)
Max
Min.Span
Output type
Current
850°C
50°C
Voltage
185°C
30°C
180°C
50°C
Output calibration
150°C
30°C
Current
Voltage
500 Ω
50 Ω
2000 Ω
50 Ω
Burn-out values
Max. output value
Min. output value
Output load Resistance - Rload
Current output
Voltage output
Short circuit current
Response time
-
www.datexel.it
OUTPUT A
INPUT
V
RTD/RES
OUTPUT B
V
DC SUPPLY
+
-
Min
Max
Min Span
0 mA
20 mA
4 mA
0 V
10 V
1 V
± 7 uA
± 5 mV
22 mA or 10.6 V
0 mA or -0.6 V
< 500 Ω
> 10 KΩ
26 mA max.
500 ms
(10÷ 90%)
about
Isolated Doubler / Converter
for RTD and resistance
configurable by Dip-Switch or PC
DAT 4631 B
DAT 4631 B
mA
mA
POWER SUPPLY
Power supply voltage
Reverse polarity protection
Current consumption
Current output
Voltage output
ISOLATION
Among all ways
TEMPERATURE AND HUMIDITY
Operative temperature
Storage temperature
Humidity (not condensed)
HOUSING
Material
Self-extinguishing plastic
Mounting
DIN rail in compliance
with EN-50022 and
EN-50035
Weight
about 90 g.
EMC ( for industrial environments )
Immunity
Emission
18 .. 30 Vdc
60 Vdc max
55 mA max.
25 mA max.
1500 Vac,
50 Hz, 1 min
-20°C .. +60°C
-40°C.. +85°C
0 .. 90 %
EN 61000-6-2
EN 61000-6-4

Advertisement

loading

Summary of Contents for Datexel DAT 4631 B

  • Page 1 GENERAL DESCRIPTION The isolated doubler/converter DAT 4631 B is able to measure and linearise the standard RTDs and resistances with 2 or 3 wires cable compensation . In function of programming, the measured values are converted in a current or voltage signal. The device guarantees high accuracy and performances stability both versus time and temperature.
  • Page 2 PROGRAMMING CONFIGURATION BY PC PRODAT By software DATESOFT it is possible to: - set the default programming of the device; POWER SUPPLY - program the options not available with the dip-switch; UNIT (burn-out level, etc...); - read, in real time, the input and output measures; V+ V- - follow the dip-switches configuration wizard.
  • Page 3 TAB.3a – Settings for Resistance < 2KOhm Zero Full scale Ω Ω Ω Ω Ω Default Default 1150 1600 1175 1650 1200 1700 1225 1750 1250 1800 1275 1850 1300 1900 1325 1950 1350 2000 1375 2000 1000 1400 2000 1025 1425 2000...
  • Page 4 DAT 4631B / Pt100 / 0 ÷ 200 °C / 4 ÷ 20 mA / 3 wires Input type Input range Output range Options ED.03.08-R.04 Datexel reserves its rights to modify totally or in part the characteristics of its products without notice at any time...